Commands
4
:CHANnel<x>[:VOLTage]:LSCale:DISPlay
type:SUBunit
Function Sets or queries the unit prefix that is used when
the linear-scaling result display mode is set to
Float for a module that can measure analog
voltage.
Syntax
:CHANnel<x>[:VOLTage]:LSCale:
DISPlaytype:SUBunit {AUTO|NONE|PICO|
NANO|MICRo|MILI|KILO|MEGA|GIGA|TERA}
:CHANnel<x>[:VOLTage]:LSCale:
DISPlaytype:SUBunit?
<x> = 1 to 4
Example
:CHANNEL1:VOLTAGE:LSCALE:
DISPLAYTYPE:SUBUNIT AUTO
:CHANNEL1:VOLTAGE:LSCALE:
DISPLAYTYPE:SUBUNIT?
-> :CHANNEL1:VOLTAGE:LSCALE:
DISPLAYTYPE:SUBUNIT AUTO
:CHANnel<x>[:VOLTage]:LSCale:GETMeas
ure
Function Executes the measurement of the linear scaling
P1:X or P2:X value of a module that can measure
analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:LSCale:
GETMeasure {P1X|P2X}
<x> = 1 to 4
:CHANnel<x>[:VOLTage]:LSCale:MODE
Function Sets or queries the linear scaling mode of a
module that can measure analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:LSCale:
MODE {AXB|OFF|P12}
:CHANnel<x>[:VOLTage]:LSCale:MODE?
<x> = 1 to 4
Example
:CHANNEL1:VOLTAGE:LSCALE:MODE AXB
:CHANNEL1:VOLTAGE:LSCALE:MODE?
-> :CHANNEL1:VOLTAGE:LSCALE:MODE OFF
:CHANnel<x>[:VOLTage]:LSCale:{P1X|P1
Y|P2X|P2Y}
Function Sets or queries the linear scaling P1:X, P1:Y,
P2:X, or P2:Y value of a module that can
measure analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:LSCale:{P1X|
P1Y|P2X|P2Y} {<NRf>}
:CHANnel<x>[:VOLTage]:LSCale:{P1X|
P1Y|P2X|P2Y}?
<x> = 1 to 4
<NRf>ofP1X,P2X=−9.9999E+30to−1E−30,0,
1E−30to9.9999E+30
<NRf>ofP1Y,P2Y=−9.9999E+30to−1E−30,0,
1E−30to9.9999E+30
Example
:CHANNEL1:VOLTAGE:LSCALE:P1X 1
:CHANNEL1:VOLTAGE:LSCALE:P1X?
-> :CHANNEL1:VOLTAGE:LSCALE:P1X 1
:CHANnel<x>[:VOLTage]:LSCale:UNIT
Function Sets or queries the linear-scaling unit string of a
module that can measure analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:LSCale:
UNIT {<String>}
:CHANnel<x>[:VOLTage]:LSCale:UNIT?
<x> = 1 to 4
<String> = Up to 4 characters
Example
CHANNEL1:VOLTAGE:LSCALE:UNIT “UU”
CHANNEL1:VOLTAGE:LSCALE:UNIT?
-> CHANNEL1:VOLTAGE:LSCALE:UNIT “UU”
:CHANnel<x>[:VOLTage]:POSition
Function Sets or queries the vertical position for a module
that can measure analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:
POSition {<NRf>}
:CHANnel<x>[:VOLTage]:POSition?
<x> = 1 to 4
<NRf> = –5.00 to 5.00 (in 0.01 div steps)
Example
:CHANNEL1:VOLTAGE:POSITION 1.00
:CHANNEL1:VOLTAGE:POSITION?
-> :CHANNEL1:VOLTAGE:POSITION 1.00
:CHANnel<x>[:VOLTage]:PROBe
Function Sets or queries the probe type of a module that
can measure analog voltage.
Syntax
:CHANnel<x>[:VOLTage]:PROBe {<NRf>|
C1|C10|C100|C400}
:CHANnel<x>[:VOLTage]:PROBe?
<x> = 1 to 4
<NRf> = 1, 10, 100, 1000
Example
:CHANNEL1:VOLTAGE:PROBE 10
:CHANNEL1:VOLTAGE:PROBE?
-> :CHANNEL1:VOLTAGE:PROBE 10
Description You cannot use this command/query on the
701261 (UNIVERSAL), 701262 (UNIVERSAL
(AFF)), 701265 (TEMP/HPV), 720266 (TEMP/
HPV), or 720268 (HV (with AFF, RMS)).
:CHANnel<x>[:VOLTage]:SCALe
Function Sets or queries the upper and lower limits of the
screen for a module that can measure analog
voltage.
Syntax
:CHANnel<x>[:VOLTage]:
SCALe {<Voltage>,<Voltage>|
<Current>,<Current>|<NRf>,<NRf>}
:CHANnel<x>[:VOLTage]:SCALe?
<x> = 1 to 4
<Voltage>, <Current>, and <NRf> =
The selectable range varies depending on the
range setting.
Example
:CHANNEL1:VOLTAGE:SCALE 250,-250
:CHANNEL1:VOLTAGE:SCALE?
-> :CHANNEL1:VOLTAGE:SCALE
250.000E+00,-250.000E+00
4.6 CHANnel Group