4-78
IM DL350-17EN
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype?
Function Queries all linear-scaling result display-mode
settings of a 4-CH module, 16-CH voltage input
module, or 16-CH temperature/voltage input
module.
Syntax
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype?
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:DECimalnum
Function Sets or queries the decimal place that is used
when the linear-scaling result display mode is
set to Float for a 4-CH module, 16-CH voltage
input module, or 16-CH temperature/voltage input
module.
Syntax
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:
DECimalnum {<NRf>|AUTO}
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:DECimalnum?
4-CH module (720254)
<x1> = 1 to 4
<x2> = 1, 2
16-CH Voltage Input Module (720220)
<x1> = 1, 3
<x2> = 1 to 16
16-CH Temperature/Voltage Input Module
(720221)
<x1> = 1, 3
<x2> = 1 to 16
<NRf> = 0 to 3
Example
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:DECIMALNUM AUTO
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:DECIMALNUM?
-> :CHANNEL1:VOLTAGE:SCHANNEL1:
LSCALE:DISPLAYTYPE:DECIMALNUM AUTO
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:MODE
Function Sets or queries the linear-scaling result display
mode of a 4-CH module, 16-CH voltage input
module, or 16-CH temperature/voltage input
module.
Syntax
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:MODE {EXPonent|
FLOating}
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:MODE?
4-CH module (720254)
<x1> = 1 to 4
<x2> = 1, 2
16-CH Voltage Input Module (720220)
<x1> = 1, 3
<x2> = 1 to 16
16-CH Temperature/Voltage Input Module
(720221)
<x1> = 1, 3
<x2> = 1 to 16
Example
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:MODE EXPONENT
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:MODE?
-> :CHANNEL1:VOLTAGE:LSCALE:
DISPLAYTYPE:MODE EXPONENT
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:SUBunit
Function Sets or queries the unit prefix that is used when
the linear-scaling result display mode is set to
Float for a 4-CH module, 16-CH voltage input
module, or 16-CH temperature/voltage input
module.
Syntax
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:SUBunit {AUTO|
NONE|PICO|NANO|MICRo|MILI|KILO|MEGA|
GIGA|TERA}
:CHANnel<x1>[:VOLTage]:SCHannel<x2>:
LSCale:DISPlaytype:SUBunit?
4-CH module (720254)
<x1> = 1 to 4
<x2> = 1, 2
16-CH Voltage Input Module (720220)
<x1> = 1, 3
<x2> = 1 to 16
16-CH Temperature/Voltage Input Module
(720221)
<x1> = 1, 3
<x2> = 1 to 16
Example
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:SUBUNIT AUTO
:CHANNEL1:VOLTAGE:SCHANNEL1:LSCALE:
DISPLAYTYPE:SUBUNIT?
-> :CHANNEL1:VOLTAGE:SCHANNEL1:
LSCALE:DISPLAYTYPE:SUBUNIT AUTO