4-46
IM DL350-17EN
:CHANnel<x1>:CAN:SCHannel<x2>:FACTor
Function Sets or queries the scaling coefficient (the value
per bit) of the specified sub channel on a module
that can monitor CAN bus signals.
Syntax
:CHANnel<x1>:CAN:SCHannel<x2>:
FACTor {<NRf>}
:CHANnel<x1>:CAN:SCHannel<x2>:
FACTor?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x1> = 1, 3
<x2> = 1 to 60
<NRf> = –10.000E+30 to 10.000E+30
Example
:CHANNEL3:CAN:SCHANNEL1:FACTOR 5E15
:CHANNEL3:CAN:SCHANNEL1:FACTOR?
-> :CHANNEL3:CAN:SCHANNEL1:
FACTOR 5.00000E+15
Description This command is valid when the data type
(:CHANnel<x>:CAN:SCHannel<x>:VTYPe) is set
to UNSigned or SIGNed.
:CHANnel<x1>:CAN:SCHannel<x2>:INPut
Function Sets or queries the input ON/OFF state of the
specified sub channel on a module that can
monitor CAN bus signals.
Syntax
:CHANnel<x1>:CAN:SCHannel<x2>:
INPut {<Boolean>}
:CHANnel<x1>:CAN:SCHannel<x2>:INPut?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x1> = 1, 3
<x2> = 1 to 60
Example
:CHANNEL3:CAN:SCHANNEL1:INPUT ON
:CHANNEL3:CAN:SCHANNEL1:INPUT?
-> :CHANNEL3:CAN:SCHANNEL1:INPUT 1
:CHANnel<x1>:CAN:SCHannel<x2>:LABel
Function Sets or queries the label string of the specified
sub channel on a module that can monitor CAN
bus signals.
Syntax
:CHANnel<x1>:CAN:SCHannel<x2>:
LABel {<String>}
:CHANnel<x1>:CAN:SCHannel<x2>:LABel?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x1> = 1, 3
<x2> = 1 to 60
<String> = Up to 16 characters
Example
:CHANNEL3:CAN:SCHANNEL1:LABEL "AAAA"
:CHANNEL3:CAN:SCHANNEL1:LABEL?
-> :CHANNEL3:CAN:SCHANNEL1:
LABEL "AAAA"
:CHANnel<x1>:CAN:SCHannel<x2>:MFORm
at
Function Sets or queries the message format of the
specified sub channel on a module that can
monitor CAN bus signals.
Syntax
:CHANnel<x1>:CAN:SCHannel<x2>:
MFORmat {EXTended|STANdard}
:CHANnel<x1>:CAN:SCHannel<x2>:
MFORmat?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x1> = 1, 3
<x2> = 1 to 60
Example
:CHANNEL3:CAN:SCHANNEL1
:MFORMAT STANDARD
:CHANNEL3:CAN:SCHANNEL1:MFORMAT?
-> :CHANNEL3:CAN:SCHANNEL1:
MFORMAT STANDARD
:CHANnel<x1>:CAN:SCHannel<x2>:MID
Function Sets or queries the message ID of the specified
sub channel on a module that can monitor CAN
bus signals.
Syntax
:CHANnel<x1>:CAN:SCHannel<x2>:
MID {<String>}
:CHANnel<x1>:CAN:SCHannel<x2>:MID?
CAN Bus Monitor Module (720240) or
the CAN/CAN FD monitor module (720242)
<x1> = 1 to 4
CAN & LIN Bus Monitor Module (720241)
<x1> = 1, 3
<x2> = 1 to 60
When the :CHANnel<x>:CAN:OSOut:MFORmat
command is set to STANdard
<String> = “0” to “7FF”
When the :CHANnel<x>:CAN:OSOut:MFORmat
command is set to EXTended
<String> = “0” to “1FFFFFFF”
Example
:CHANNEL3:CAN:SCHANNEL1:MID "7FF"
:CHANNEL3:CAN:SCHANNEL1:MID?
-> :CHANNEL1:CAN:SCHANNEL1:MID "7FF"
Description If a value outside the range is specified, error
151, “Invalid string data,” will occur.
4.6 CHANnel Group

Other manuals for YOKOGAWA DL350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL350 and is the answer not in the manual?

YOKOGAWA DL350 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL350
CategoryRecording Equipment
LanguageEnglish

Related product manuals