4-50
IM DL350-17EN
:CHANnel<x>:FREQ:INPut:SLOPe
Function Sets or queries the input slope of a frequency
module.
Syntax
:CHANnel<x>:FREQ:INPut:SLOPe {FALL|
RISE}
:CHANnel<x>:FREQ:INPut:SLOPe?
<x> = 1 to 4
Example
:CHANNEL1:FREQ:INPUT:SLOPE RISE
:CHANNEL1:FREQ:INPUT:SLOPE?
-> :CHANNEL1:FREQ:INPUT:SLOPE RISE
:CHANnel<x>:FREQ:INPut:THReshold
Function Sets or queries the threshold level of a frequency
module.
Syntax
:CHANnel<x>:FREQ:INPut:
THReshold {<Voltage>}
:CHANnel<x>:FREQ:INPut:THReshold?
<x> = 1 to 4
<Voltage>=100to−100V
Example
:CHANNEL1:FREQ:INPUT:
THRESHOLD 0.00000E+00
:CHANNEL1:FREQ:INPUT:THRESHOLD?
-> :CHANNEL1:FREQ:INPUT:THRESHOLD
0.00000E+00
:CHANnel<x>:FREQ:INPut:VRANge
Function Sets or queries the voltage range of a frequency
module.
Syntax
:CHANnel<x>:FREQ:INPut:
VRANge {<Voltage>}
:CHANnel<x>:FREQ:INPut:VRANge?
<x> = 1 to 4
<Voltage> = 1 to 500V
Example
:CHANNEL1:FREQ:INPUT:VRANGE 10
:CHANNEL1:FREQ:INPUT:VRANGE?
-> :CHANNEL1:FREQ:INPUT:VRANGE 10
:CHANnel<x>:FREQ:LSCale?
Function Queries all the linear scaling settings of a
frequency module.
Syntax
:CHANnel<x>:FREQ:LSCale?
:CHANnel<x>:FREQ:LSCale:AVALue
Function Sets or queries the scaling coefficient A that is
used during linear scaling for a frequency module.
Syntax
:CHANnel<x>:FREQ:LSCale:
AVALue {<NRf>}
:CHANnel<x>:FREQ:LSCale:AVALue?
<x> = 1 to 4
<NRf>=−9.9999E+30to−1E−30,
1E−30to9.9999E+30
Example
:CHANNEL1:FREQ:LSCALE:
AVALUE 25.0000E+00
:CHANNEL1:FREQ:LSCALE:AVALUE?
-> :CHANNEL1:FREQ:LSCALE:
AVALUE 25.0000E+00
Description The coefficient cannot be set to 0.
:CHANnel<x>:FREQ:LSCale:BVALue
Function Sets or queries the scaling coefficient B that is
used during linear scaling for a frequency module.
Syntax
:CHANnel<x>:FREQ:LSCale:
BVALue {<NRf>}
:CHANnel<x>:FREQ:LSCale:BVALue?
<x> = 1 to 4
<NRf>=−9.9999E+30to−1E−30,
1E−30to9.9999E+30
Example
:CHANNEL1:FREQ:LSCALE:
BVALUE -25.0000E+00
:CHANNEL1:FREQ:LSCALE:BVALUE?
-> :CHANNEL1:FREQ:LSCALE:
BVALUE -25.0000E+00
:CHANnel<x>:FREQ:LSCale:GETMeasure
Function Executes the measurement of the linear scaling
P1:X or P2:X value of a frequency module.
Syntax
:CHANnel<x>:FREQ:LSCale:
GETMeasure {P1X|P2X}
<x> = 1 to 4
Example
:CHANnel1:FREQ:LSCale:GETMeasure P1X
4.6 CHANnel Group

Other manuals for YOKOGAWA DL350