Commands
1
2
3
4
5
App
Index
:CHANnel<x>:STRain:LSCale:{P1X|P1Y|P
2X|P2Y}
Function Sets or queries the linear scaling P1:X, P1:Y,
P2:X, or P2:Y value of a strain module.
Syntax
:CHANnel<x>:STRain:LSCale:{P1X|P1Y|
P2X|P2Y} {<NRf>}
:CHANnel<x>:STRain:LSCale:{P1X|P1Y|
P2X|P2Y}?
<x> = 1 to 4
<NRf> of P1X, P2X =
−9.9999E+30to−1E−30,0,
1E−30to9.9999E+30
<NRf> of P1Y, P2Y =
−9.9999E+30to−1E−30,0,
1E−30to9.9999E+30
Example
:CHANNEL1:STRAIN:LSCALE:
P1X 1.00000E+00
:CHANNEL1:STRAIN:LSCALE:P1X?
-> :CHANNEL1:STRAIN:LSCALE:
P1X 1.00000E+00
:CHANnel<x>:STRain:LSCale:SHUNt
Function Executes shunt calibration.
Syntax
:CHANnel<x>:STRain:LSCale:SHUNt
<x> = 1 to 4
:CHANnel<x>:STRain:LSCale:UNIT
Function Sets or queries the unit string for linear scaling of
the strain module.
Syntax
:CHANnel<x>:STRain:LSCale:
UNIT {<String>}
:CHANnel<x>:STRain:LSCale:UNIT?
<x> = 1 to 4
<String> = Up to 4 characters
Example
:CHANNEL1:STRAIN:LSCALE:UNIT “UU”
:CHANNEL1:STRAIN:LSCALE:UNIT?
-> :CHANNEL1:STRAIN:LSCALE:UNIT “UU”
:CHANnel<x>:STRain:RANGe
Function Sets or queries the measurement range of a
strain module.
Syntax
:CHANnel<x>:STRain:RANGe {<NRf>}
:CHANnel<x>:STRain:RANGe?
<x> = 1 to 4
<NRf> = 0.25, 0.5, 1, 2.5, 5, 10 (when the unit is
mV or V),
500, 1000, 2000, 5000, 10000, 20000
(whentheunitisμSTR)
Example
:CHANNEL11:STRAIN:RANGE 20000
:CHANNEL11:STRAIN:RANGE?
-> :CHANNEL11:STRAIN:RANGE 20000
:CHANnel<x>:STRain:SCALe
Function Sets or queries the upper and lower limits of the
screen for a strain module.
Syntax
:CHANnel<x>:STRain:
SCALe {<NRf>,<NRf>}
:CHANnel<x>:STRain:SCALe?
<x> = 1 to 4
<NRf>=−15.0000to15.0000(whentheunitis
mV/V)
−30000to30000(whentheunitisµSTR)
−9.9999E+30to9.9999E+30(forlinear
scaling)
Example
:CHANNEL1:STRAIN:SCALE 5000,-5000
:CHANNEL1:STRAIN:SCALE?
-> :CHANNEL1:STRAIN:
SCALE 5.000000E+03,-5.000000E+03
:CHANnel<x>:STRain:UNIT
Function Sets or queries the unit of a strain module.
Syntax
:CHANnel<x>:STRain:UNIT {MV|USTR}
:CHANnel<x>:STRain:UNIT?
<x> = 1 to 4
Example
:CHANNEL11:STRAIN:UNIT USTR
:CHANNEL11:STRAIN:UNIT?
-> :CHANNEL11:STRAIN:UNIT USTR
4.6 CHANnel Group

Other manuals for YOKOGAWA DL350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL350 and is the answer not in the manual?

YOKOGAWA DL350 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL350
CategoryRecording Equipment
LanguageEnglish

Related product manuals