EasyManuals Logo
Home>YOKOGAWA>Transmitter>EJX Series

YOKOGAWA EJX Series User Manual

YOKOGAWA EJX Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
๎˜ƒ ๎˜ƒ <2.๎˜ƒ๎˜ƒHandling๎˜ƒCautions>
7
IM๎˜ƒ01C25A01-01E
IMPORTANT
For๎˜ƒcombined๎˜ƒapproval๎˜ƒtypes
Once๎˜ƒa๎˜ƒdevice๎˜ƒof๎˜ƒmultiple๎˜ƒapproval๎˜ƒtype๎˜ƒis๎˜ƒinstalled,๎˜ƒ
it๎˜ƒshould๎˜ƒnot๎˜ƒbe๎˜ƒre-installed๎˜ƒusing๎˜ƒany๎˜ƒother๎˜ƒapproval๎˜ƒ
types.๎˜ƒApply๎˜ƒa๎˜ƒpermanent๎˜ƒmark๎˜ƒin๎˜ƒthe๎˜ƒcheck๎˜ƒbox๎˜ƒof๎˜ƒ
the๎˜ƒselected๎˜ƒapproval๎˜ƒtype๎˜ƒon๎˜ƒthe๎˜ƒcerti๎šฟcation๎˜ƒlabel๎˜ƒon๎˜ƒ
the๎˜ƒtransmitter๎˜ƒto๎˜ƒdistinguish๎˜ƒit๎˜ƒfrom๎˜ƒunused๎˜ƒapproval๎˜ƒ
types.
2.4.1๎˜ƒ FM๎˜ƒApproval
a.๎˜ƒ FM๎˜ƒIntrinsically๎˜ƒSafe๎˜ƒType
Caution๎˜ƒfor๎˜ƒFM๎˜ƒintrinsically๎˜ƒsafe๎˜ƒtype.๎˜ƒ(Following๎˜ƒ
contents๎˜ƒrefer๎˜ƒโ€œDOC.๎˜ƒNo.๎˜ƒIFM022-A12โ€)
Note๎˜ƒ1.๎˜ƒ Model๎˜ƒEJX/EJA-E๎˜ƒSeries๎˜ƒDifferential,๎˜ƒgauge๎˜ƒ
and๎˜ƒabsolute๎˜ƒpressure๎˜ƒtransmitters๎˜ƒwith๎˜ƒoptional๎˜ƒ
code๎˜ƒ/FS1๎˜ƒare๎˜ƒapplicable๎˜ƒfor๎˜ƒuse๎˜ƒin๎˜ƒhazardous๎˜ƒ
locations.
โ€ข๎˜ƒ Applicable๎˜ƒStandard:๎˜ƒFM3600,๎˜ƒFM3610,๎˜ƒFM3611,๎˜ƒ
FM3810๎˜ƒ
โ€ข๎˜ƒ Intrinsically๎˜ƒSafe๎˜ƒfor๎˜ƒClass๎˜ƒI,๎˜ƒDivision๎˜ƒ1,๎˜ƒGroups๎˜ƒA,๎˜ƒ
B,๎˜ƒC๎˜ƒ&๎˜ƒD.๎˜ƒClass๎˜ƒII,๎˜ƒDivision๎˜ƒ1,๎˜ƒGroups๎˜ƒE,๎˜ƒF๎˜ƒ&๎˜ƒG๎˜ƒand๎˜ƒ
Class๎˜ƒIII,๎˜ƒDivision๎˜ƒ1,๎˜ƒClass๎˜ƒI,๎˜ƒZone๎˜ƒ0๎˜ƒin๎˜ƒHazardous๎˜ƒ
Locations,๎˜ƒAEx๎˜ƒia๎˜ƒIIC
โ€ข๎˜ƒ Nonincendive๎˜ƒfor๎˜ƒClass๎˜ƒI,๎˜ƒDivision๎˜ƒ2,๎˜ƒGroups๎˜ƒ
A,๎˜ƒB,๎˜ƒC๎˜ƒ&๎˜ƒD.๎˜ƒClass๎˜ƒII,๎˜ƒDivision๎˜ƒ2,๎˜ƒGroups๎˜ƒF๎˜ƒ&๎˜ƒG๎˜ƒ
and๎˜ƒClass๎˜ƒI,๎˜ƒZone๎˜ƒ2,๎˜ƒGroups๎˜ƒIIC,๎˜ƒin๎˜ƒHazardous๎˜ƒ
Locations.
โ€ข๎˜ƒ Outdoor๎˜ƒhazardous๎˜ƒlocations:๎˜ƒNEMA๎˜ƒTYPE๎˜ƒ4X
โ€ข๎˜ƒ Temperature๎˜ƒClass:๎˜ƒT4
โ€ข๎˜ƒ Ambient๎˜ƒtemperature:๎˜ƒโ€“60๎˜ƒto๎˜ƒ60ยฐC
Note๎˜ƒ2.๎˜ƒ Entity๎˜ƒParameters
โ€ข๎˜ƒ Intrinsically๎˜ƒSafe๎˜ƒApparatus๎˜ƒParameters
๎˜ƒ [Groups๎˜ƒA,๎˜ƒB,๎˜ƒC,๎˜ƒD,๎˜ƒE,๎˜ƒF๎˜ƒand๎˜ƒG]๎˜ƒ
Vmax๎˜ƒ=๎˜ƒ30๎˜ƒV Ci๎˜ƒ=๎˜ƒ6๎˜ƒnF
Imax๎˜ƒ=๎˜ƒ200๎˜ƒmA Li๎˜ƒ=๎˜ƒ0๎˜ƒยตH
Pmax๎˜ƒ=๎˜ƒ1๎˜ƒW
*๎˜ƒ Associated๎˜ƒApparatus๎˜ƒParameters
๎˜ƒ (FM๎˜ƒapproved๎˜ƒbarriers)
Voc๎˜ƒโ‰ค๎˜ƒ30๎˜ƒV Ca๎˜ƒ>๎˜ƒ6๎˜ƒnF
Isc๎˜ƒโ‰ค๎˜ƒ200๎˜ƒmA La๎˜ƒ>๎˜ƒ0๎˜ƒยตH
Pmax๎˜ƒโ‰ค๎˜ƒ1W
โ€ข๎˜ƒ Intrinsically๎˜ƒSafe๎˜ƒApparatus๎˜ƒParameters
๎˜ƒ [Groups๎˜ƒC,๎˜ƒD,๎˜ƒE,๎˜ƒF๎˜ƒand๎˜ƒG]
Vmax๎˜ƒ=๎˜ƒ30๎˜ƒV Ci๎˜ƒ=๎˜ƒ6๎˜ƒnF
Imax๎˜ƒ=๎˜ƒ225๎˜ƒmA Li๎˜ƒ=๎˜ƒ0๎˜ƒยตH
Pmax๎˜ƒ=๎˜ƒ1๎˜ƒW
*๎˜ƒ Associated๎˜ƒApparatus๎˜ƒParameters
๎˜ƒ (FM๎˜ƒapproved๎˜ƒbarriers)
Voc๎˜ƒโ‰ค๎˜ƒ30๎˜ƒV Ca๎˜ƒ>๎˜ƒ6๎˜ƒnF
Isc๎˜ƒโ‰ค๎˜ƒ225๎˜ƒmA La๎˜ƒ>๎˜ƒ0๎˜ƒยตH
Pmax๎˜ƒโ‰ค๎˜ƒ1๎˜ƒW
โ€ข๎˜ƒ Entity๎˜ƒInstallation๎˜ƒRequirements
๎˜ƒ Vmax๎˜ƒโ‰ฅ๎˜ƒVoc๎˜ƒor๎˜ƒUo๎˜ƒor๎˜ƒVt,๎˜ƒImax๎˜ƒโ‰ฅ๎˜ƒIsc๎˜ƒor๎˜ƒIo๎˜ƒor๎˜ƒIt,๎˜ƒ
๎˜ƒ Pmax๎˜ƒ(or๎˜ƒPo)๎˜ƒโ‰ค๎˜ƒPi,๎˜ƒCa๎˜ƒor๎˜ƒCo๎˜ƒโ‰ฅ๎˜ƒCi๎˜ƒ+๎˜ƒCcable,
๎˜ƒ La๎˜ƒor๎˜ƒLo๎˜ƒโ‰ฅ๎˜ƒLi๎˜ƒ+๎˜ƒLcable
Note๎˜ƒ3.๎˜ƒ Installation
โ€ข๎˜ƒ Barrier๎˜ƒmust๎˜ƒbe๎˜ƒinstalled๎˜ƒin๎˜ƒan๎˜ƒenclosure๎˜ƒthat๎˜ƒ
meets๎˜ƒthe๎˜ƒrequirements๎˜ƒof๎˜ƒANSI/ISA๎˜ƒS82.01.
โ€ข๎˜ƒ Control๎˜ƒequipment๎˜ƒconnected๎˜ƒto๎˜ƒbarrier๎˜ƒmust๎˜ƒnot๎˜ƒ
use๎˜ƒor๎˜ƒgenerate๎˜ƒmore๎˜ƒthan๎˜ƒ250๎˜ƒV๎˜ƒrms๎˜ƒor๎˜ƒV๎˜ƒdc.
โ€ข๎˜ƒ Installation๎˜ƒshould๎˜ƒbe๎˜ƒin๎˜ƒaccordance๎˜ƒwith๎˜ƒANSI/ISA๎˜ƒ
RP12.6๎˜ƒโ€œInstallation๎˜ƒof๎˜ƒIntrinsically๎˜ƒSafe๎˜ƒSystems๎˜ƒ
for๎˜ƒHazardous๎˜ƒ(Classi๎šฟed)๎˜ƒLocationsโ€๎˜ƒand๎˜ƒthe๎˜ƒ
National๎˜ƒElectric๎˜ƒCode๎˜ƒ(ANSI/NFPA๎˜ƒ70).
โ€ข๎˜ƒ The๎˜ƒcon๎šฟguration๎˜ƒof๎˜ƒassociated๎˜ƒapparatus๎˜ƒmust๎˜ƒbe๎˜ƒ
FMRC๎˜ƒApproved.
โ€ข๎˜ƒ Dust-tight๎˜ƒconduit๎˜ƒseal๎˜ƒmust๎˜ƒbe๎˜ƒused๎˜ƒwhen๎˜ƒ
installed๎˜ƒin๎˜ƒa๎˜ƒClass๎˜ƒII,๎˜ƒIII,๎˜ƒGroup๎˜ƒE,๎˜ƒF๎˜ƒand๎˜ƒG๎˜ƒ
environments.
โ€ข๎˜ƒ Associated๎˜ƒapparatus๎˜ƒmanufacturerโ€™s๎˜ƒinstallation๎˜ƒ
drawing๎˜ƒmust๎˜ƒbe๎˜ƒfollowed๎˜ƒwhen๎˜ƒinstalling๎˜ƒthis๎˜ƒ
apparatus.
โ€ข๎˜ƒ The๎˜ƒmaximum๎˜ƒpower๎˜ƒdelivered๎˜ƒfrom๎˜ƒthe๎˜ƒbarrier๎˜ƒ
must๎˜ƒnot๎˜ƒexceed๎˜ƒ1๎˜ƒW.
โ€ข๎˜ƒ Note๎˜ƒa๎˜ƒwarning๎˜ƒlabel๎˜ƒworded๎˜ƒโ€œSUBSTITUTION๎˜ƒ
OF๎˜ƒCOMPONENTS๎˜ƒMAY๎˜ƒIMPAIR๎˜ƒINTRINSIC๎˜ƒ
SAFETY,โ€๎˜ƒand๎˜ƒโ€œINSTALL๎˜ƒIN๎˜ƒACCORDANCE๎˜ƒWITH๎˜ƒ
DOC.๎˜ƒNo.๎˜ƒIFM022-A12โ€
Note๎˜ƒ4.๎˜ƒ Maintenance๎˜ƒand๎˜ƒRepair
โ€ข๎˜ƒ The๎˜ƒinstrument๎˜ƒmodi๎šฟcation๎˜ƒor๎˜ƒparts๎˜ƒreplacement๎˜ƒ
by๎˜ƒother๎˜ƒthan๎˜ƒauthorized๎˜ƒrepresentative๎˜ƒof๎˜ƒ
Yokogawa๎˜ƒElectric๎˜ƒCorporation๎˜ƒis๎˜ƒprohibited๎˜ƒand๎˜ƒ
will๎˜ƒvoid๎˜ƒFactory๎˜ƒMutual๎˜ƒIntrinsically๎˜ƒsafe๎˜ƒand๎˜ƒ
Nonincendive๎˜ƒApproval.
F0204.ai
Class I, II, III, Division 1,
Groups A, B, C, D, E, F, G
Class 1, Zone 0 in
Hazardous (Classified)
Locations AEx ia IIC
Pressure Transmitters
Safety Barrier
Supply
Hazardous Location Nonhazardous Location
General
Purpose
Equipment
+
โ€“
+
โ€“
+
โ€“
+
โ€“
[Intrinsically Safe]
Handling๎˜ƒCautions
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA EJX Series and is the answer not in the manual?

YOKOGAWA EJX Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelEJX Series
CategoryTransmitter
LanguageEnglish

Related product manuals