<9. General Specications>
9-10
IM 01C25F01-01E
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D.
*2: Not applicable for option code /AL.
*3: Applicable for output signal code D, E, and J.
*4: Not applicable for measurement range 70 MPa (EJX60A D range and EJA50E /HG).
*5: Applicableonlyforprocessconnectioncode0,1,2,3,4,5,6,7,8,9orA,forthosemodelswhichhaveadenitionof“process
connection”intheirsufxcodestructure.
Not applicable for a diaphragm seal system (EJXC40A, EJXC50A, EJAC50E, EJXC80A or EJAC80E).
*6: Not applicable with color change option.
*7: Thisspecicationisincludedwhenampliercasecode2isspecied.
*8: Check/Externalindicatorterminalscannotbeusedwhenthisoptioncodeisspecied.NotapplicableforoutputsignalcodeF.
*9:
TheunitofMWP(Max.workingpressure)onthenameplateofahousingisthesameunitasspeciedbyoptioncodesD1,D3,andD4.
*10: ApplicableforoutputsignalcodesD,EandJ.Thehardwareerrorindicatesfaultyamplierorcapsule.
*11: Also see ‘Ordering Information’.
*12: Materialtraceabilitycertication,perEN102043.1B.
*13: Applicable for capsule code A.
*14: Applicable for capsule code B.
*15: Applicable for capsule code C.
*16: Applicable for capsule code D of EJ510 and EJ530.
*17: Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).
*18: Applicable for wetted parts material code S.
*19: Applicable only for output signal code -E and -J.
*20: Thechangeofpressureuctuationismonitoredandthendetectstheimpulselineblockage.SeeTI01C25A31-01Efordetailed
technical information required for using this function.
*21: Applicable for measurement span code D. If compliance with category III is needed, specify this option code.
*22: Applicable for EJX630A, EJA510E and EJA530E.
Not applicable for the combination of measurement span code A and wetted parts material code H.
Not applicable for option code K2, K3 or A1.
WhenspeciedrangevalueincludesminusvalueforAcapsule,theaccuracyshallbethestandardaccuracyevenifhighaccuracy
option(/HAC)isspecied.
*23: Applicable for capsule code D of EJX610A and EJX630A. Applicable also for EJA510E and EJA530E with /HG.
*24: OutputstatusatCPUfailureandhardwareerroris−5%,0.8VDCorlessforoutputsignalcodeQ.
*25: The 1 to 5 V voltage output corresponding to 4 to 20 mA current output is applied to output signal code Q which is non-compliant to
NAMUR NE43.
*26: Applicable for capsule code D of EJA510E and EJA530E.
OptionalSpecications(forDiaphragmSealSystem)
Following table shows the option codes dedicated for EJXC50A or EJAC50E Diaphragm Seal System. These
codescannotbespeciedwithoutadiaphragmsealsystem.PleaserefertotheIM01C25W01-01EN.
Item Description Code
Oil-prohibited use Degrease cleansing treatment K11
Degreasecleansingtreatmentanduorinatedoillledcapsule.
Operatingtemperature−20to80°C(−4to176°F)
K12
Oil-prohibited use with
dehydrating treatment
Degrease cleansing and dehydrating treatment K15
Degreasecleansinganddehydratingtreatmentwithuorinatedoillledcapsule.
Operatingtemperature−20to80°C(−4to176°F)
K16
Capsulelluid Fluorinatedoillledincapsule.
Operatingtemperature−20to80°C(−4to176°F)
K13