IM 05P02D41-11EN page 1/14
Contents
1. Safety Precautions
2. ModelandSufxCodes
3. How to Install
4. HardwareSpecications
5. HowtoConnectWires
6. TerminalWiringDiagrams
Introduction
ThankyouforpurchasingtheUP35A/UP32AProgramController.
Thisoperationguidedescribesthebasicoperationsrelatedtothesingle-loopcontrol
functionoftheUP35A/UP32A.Theguideshouldbeprovidedtotheenduserofthis
product.
Besuretoread thisoperationguidebefore usingtheproductin ordertoensure
correct operation.
Fordetailsofeachfunction,refertotheelectronicmanual.Beforeusingtheproduct,
refertothetableofModelandSufxCodestomakesurethatthedeliveredproduct
isconsistentwiththemodelandsufxcodesyouordered.Alsomakesurethatthe
followingitemsareincludedinthepackage.
•ProgramController(themodelyouordered) ..........................................x1
• Set of Brackets ........................................................................................x1
•UnitLabel(L4502VZ) ..............................................................................x1
•TagLabel(L4502VE) ..............................................................................x1
(Onlywhenordered.)
•TerminalCover(L4502XP) .....................................................................x1
•OperationGuide(thisdocument) ............................................................x7(A3size)
(InstallationandWiring,InitialSettings,Programming,Operations,andParameters)
l
TargetReaders
Thisguideisintendedforthefollowingpersonnel;
• Engineersresponsibleforinstallation,wiring,andmaintenanceoftheequipment.
• Personnelresponsiblefornormaldailyoperationoftheequipment.
1. Safety Precautions
Thefollowingsymbolisusedonthe instrument.Itindicates thepossibilityofinjury
totheuserordamagetotheinstrument,andsigniesthattheusermustrefertothe
operationguideoruser’smanualforspecialinstructions.Thesamesymbolisused
intheoperationguideanduser’smanualonpages thattheuserneedsto referto,
togetherwiththeterm“WARNING”or“CAUTION.”
Calls attention to actions or conditions that could cause serious
or fatal injury to the user, and indicates precautions that should be
taken to prevent such occurrences.
Calls attention to actions or conditions that could cause injury to
the user or damage to the instrument or property and indicates pre-
cautions that should be taken to prevent such occurrences.
Theequipmentwhollyprotectedbydoubleinsulationorreinforcedinsulation.
Functionalgroundingterminals
(Donotusethisterminalasaprotectivegroundingterminal).
Note
Identiesimportantinformationrequiredtooperatetheinstrument.
■ Warning and Disclaimer
(1) YOKOGAWAmakesnowarrantiesregardingtheproductexceptthosestatedin
theWARRANTYthatisprovidedseparately.
(2) Theproductisprovidedonan"asis"basis.YOKOGAWAassumesnoliabilityto
anypersonorentity foranylossor damage,directorindirect,arisingfromthe
useoftheproductorfromanyunpredictabledefectoftheproduct.
■ Safety,Protection,andModicationoftheProduct
(1)Inorder toprotectthe systemcontrolledbythisproductandthe productitself,
andtoensuresafe operation,observethesafety precautionsdescribedinthe
operationguide.Use oftheinstrumentinamannernot prescribedhereinmay
compromise the product's functions and the protection features inherent in the
device.Weassumenoliabilityforsafety,orresponsibilityfortheproduct'squality,
performanceorfunctionalityshouldusersfailtoobservetheseinstructionswhen
operatingtheproduct.
(2)Installation ofprotectionand/or safetycircuitswithrespect toalightning
protector;protectiveequipmentforthesystemcontrolledbytheproductandthe
productitself;foolproof orfailsafedesign ofaprocess orlineusing thesystem
controlledbytheproductortheproductitself;and/orthedesignandinstallation
ofotherprotectiveandsafetycircuitsaretobeappropriatelyimplementedasthe
customer deems necessary.
(3) Besuretouse thesparepartsapproved byYOKOGAWAwhenreplacing parts
orconsumables.
(4) Thisproductisnot designedormanufactured tobeusedin criticalapplications
thatdirectlyaffectorthreatenhuman lives.Suchapplicationsincludenuclear
powerequipment,devicesusing radioactivity,railway facilities,aviation
equipment,airnavigationfacilities,aviationfacilities,andmedicalequipment.
Ifsoused, itistheuser’sresponsibility toincludein thesystemadditional
equipmentanddevicesthatensurepersonnelsafety.
(5) Modicationoftheproductisstrictlyprohibited.
(6)
Thisproductisintendedtobehandledbyskilled/trainedpersonnelforelectricdevices.
(7)ThisproductisULRecognizedComponent.Inordertocomplywith UL
standards,end-productsarenecessary tobedesignedby thosewhohave
knowledgeoftherequirements.
l
Power Supply
Ensure that the instrument’s supply voltage matches the voltage
of the power supply before turning ON the power.
l
Do Not Use in an Explosive Atmosphere
Do not operate the instrument in locations with combustible
or explosive gases or steam. Operation in such environments
constitutes an extreme safety hazard. Use of the instrument in
environments with high concentrations of corrosive gas (H
2
S,
SO
X
, etc.) for extended periods of time may cause a failure.
l
Do Not Remove Internal Unit
The internal unit should not be removed by anyone other than
YOKOGAWA's service personnel. There are dangerous high voltage
parts inside. Additionally, do not replace the fuse by yourself.
l
Damage to the Protective Construction
Operation of the instrument in a manner not specified in the
operation guide may damage its protective construction.
This instrument is an EMC class A product. In a domestic environ-
ment this product may cause radio interference in which case the
user needs to take adequate measures.
2. ModelandSufxCodes
■ UP35A «for Standard Code Model»
Model Sufxcode
Option
code
Description
UP35A
ProgramController(Powersupply:100-240VAC)
2programpatterns/20programsegments(When
the/APoptionisspecied,4programpatterns/40
programsegments,max.20segmentsperpattern.)
(providedwithretransmissionoutputor15VDC
looppowersupply,3DIs,and3DOs)
Type1:
Basic
control
-0 Standard type
-1 Position proportional type
-2 Heating/coolingtype
Type2:
Functions
0 None
1 5additionalDOs,5additionalDIs
Type3:Open
networks
0 None
1
RS-485communication(Max.38.4kbps,2-wire/4-wire)
2
Ethernetcommunication(withserialgatewayfunction)
3
CC-Linkcommunication(withModbusmasterfunction)
4
PROFIBUS-DPcommunication(withModbusmasterfunction)
5
DeviceNetcommunication(withModbusmasterfunction)
Displaylanguage(*1)
-1
English(Default.Canbeswitchedtootherlanguagebythesetting.)
-2
German(Default.Canbeswitchedtootherlanguagebythesetting.)
-3
French(Default.Canbeswitchedtootherlanguagebythesetting.)
-4
Spanish(Default.Canbeswitchedtootherlanguagebythesetting.)
Casecolor
0 White(Lightgray)
1 Black(Lightcharcoalgray)
Fixedcode -00 Always"-00"(forStandardCodeModel)
Optioncodes
/AP
Additional
2programpatterns/20programsegments
/HA Heaterbreakalarm(*2)
/DC Powersupply24VAC/DC
/CT Coating(*3)
/CV TerminalCover
*1: English,German,French,andSpanishareavailablefortheguidedisplay.
*2: The/HAoptioncanbespecifiedonlywhentheType1codeis“-0”or“-2.”
*3: Whenthe/CToptionisspecified,theUP35Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).
■ UP32A «for Standard Code Model»
Model Sufxcode
Option
code
Description
UP32A
ProgramController(Powersupply:100-240VAC)
2programpatterns/20programsegments(When
the/APoptionisspecied,4programpatterns/40
programsegments,max.20segmentsperpattern.)
(providedwithretransmissionoutputor15VDC
looppowersupply,3DIs,and3DOs)
Type1:
Basic
control
-0 Standard type
-1 Position proportional type
-2 Heating/coolingtype
Type2:
Functions
0 None
1
RS-485communication(Max.38.4kbps,2-wire/4-wire)
2 2additionalDIs,2additionalDOs
Type3:Open
networks
0 None
3
CC-Linkcommunication(withModbusmasterfunction)(*1)
Displaylanguage(*2)
-1
English(Default.Canbeswitchedtootherlanguagebythesetting.)
-2
German(Default.Canbeswitchedtootherlanguagebythesetting.)
-3
French(Default.Canbeswitchedtootherlanguagebythesetting.)
-4
Spanish(Default.Canbeswitchedtootherlanguagebythesetting.)
Casecolor
0 White(Lightgray)
1 Black(Lightcharcoalgray)
Fixedcode -00 Always"-00"(forStandardCodeModel)
Optioncodes
/AP
Additional
2programpatterns/20programsegments
/HA Heaterbreakalarm(*3)
/DC Powersupply24VAC/DC
/CT Coating(*4)
/CV TerminalCover
*1: Type3code“3”canbespecifiedonlywhenbothType1andType2codeare“0”.
*2: English,German,French,andSpanishareavailablefortheguidedisplay.
*3:
The/HAoptioncanbespecifiedonlywhentheType1codeis“-0”or“-2”andType3codeis“0”.
*4: Whenthe/CToptionisspecified,theUP32Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).
■ Accessories (sold separately)
Thefollowingisanaccessorysoldseparately.
• LL50AParameterSettingSoftware
Model Sufxcode Description
LL50A -00 ParameterSettingSoftware
• ExternalPrecisionResistor
Model Sufxcode Description
X010 SeetheGeneralSpecications(*) ResistanceModule
*:Necessarytoinputthecurrentsignaltothevoltageinputterminal.
• TerminalCover:ModelUTAP001
• TerminalCover
ModelUTAP001forUP35A,ModelUTAP002forUP32A
• Manuals
Note:Manualscanbedownloadedfromawebsite.
URL:http://www.yokogawa.com/ns/ut/im/
• Brackets
Partnumber:L4502TP(2pcsforupperandlowersides)
3. How to Install
■ Installation Location
Theinstrumentshouldbeinstalledinindoor locationsmeetingthe following
conditions:
• Instrumented panel
Thisinstrumentisdesignedto bemountedinan instrumentedpanel.Mountthe
instrumentinalocationwhereitsterminalswillnotinadvertentlybetouched.
• Well ventilated locations
Mounttheinstrumentinwellventilatedlocationstopreventtheinstrument’sinter-
naltemperaturefromrising.
However,makesurethattheterminalportionsarenotexposedtowind.Exposure
to wind may cause the temperature sensor accuracy to deteriorate. To mount mul-
tipleindicatingcontrollers, seetheexternal dimensions/panelcutoutdimensions
whichfollow.Ifmountingotherinstrumentsadjacenttotheinstrument,complywith
thesepanelcutoutdimensionstoprovidesufcientclearancebetweentheinstru-
ments.
• Locations with little mechanical vibration
Installtheinstrumentinalocationsubjecttolittlemechanicalvibration.
• Horizontal location
Mounttheinstrumenthorizontallyandensurethatitislevel,withnoinclinationto
therightorleft.
Front panel
of controller
Keep this angle
within 30°
Rear of
controller
30°
Note
Iftheinstrument ismovedfrom alocationwith lowtemperatureand lowhumidity
toaplacewith hightemperatureandhighhumidity,orifthetemperaturechanges
rapidly,condensationwill result.Moreover,in thecaseof thermocoupleinputs,
measurementerrorswillresult.Toavoidsuchasituation,leavetheinstrumentinthe
newenvironmentunderambientconditionsformorethan1hourpriortousingit.
Donotmounttheinstrumentinthefollowinglocations:
• Outdoors
• Locations subject to direct sunlight or close to a heater
Installtheinstrumentinalocationwithstabletemperaturesthatremainclosetoan
averagetemperatureof23°C.Donotmountitinlocationssubjecttodirectsunlight
orclosetoaheater.Doingsoadverselyaffectstheinstrument.
• Locations with substantial amounts of oily fumes, steam, moisture, dust, or
corrosive gases
Thepresenceofoilyfumes,steam,moisture,dust,or corrosivegasesadversely
affectstheinstrument.Donotmounttheinstrumentinlocationssubjecttoanyof
thesesubstances.
• Areasnearelectromagneticeldgeneratingsources
Donotplacemagnetsortoolsthatgeneratemagnetismneartheinstrument.Ifthe
instrumentisusedin locationsclosetoa strongelectromagneticeldgenerating
source,themagneticeldmaycausemeasurementerrors.
• Locationswherethedisplayisdifculttosee
TheinstrumentusesanLCD forthedisplayunit,andthiscanbedifculttosee
fromextremelyobliqueangles.Mounttheinstrumentinalocationwhereitcanbe
seenasmuchaspossiblefromthefront.
• Areasclosetoammablearticles
Absolutelydonotplace theinstrumentdirectlyonam-
mablesurfaces.Ifsuchacircumstanceis unavoidable
andtheinstrumentmustbeplacedclosetoaammable
item,provideashieldforitmadeof1.43mmthickplated
steel or 1.6 mm thick unplated steel with a space of at
least150mmbetweenitandtheinstrumentonthetop,
bottom,andsides.
• Areas subject to being splashed with water
Be sure to turn OFF the power supply to the controller before in-
stalling it on the panel to avoid an electric shock.
www.yokogawa.com/ns
YOKOGAWA ELECTRIC CORPORATION
Network Solutions Business Division
2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPAN
YOKOGAWA CORPORATION OF AMERICA
Head office and for product sales
2 Dart Road, Newnan, Georgia 30265, USA
YOKOGAWA EUROPE B.V.
Headquarters
Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS
All Rights Reserved, Copyright © 2010 Yokogawa Electric Corporation
150 mm150 mm
150 mm
150 mm
Operation
Guide
IM 05P02D41-11EN
UP35A/UP32A
Program Controller
Operation Guide
This operation guide describes installation, wiring, and other tasks required to make the
controller ready for operation.
4th Edition : Mar. 2016
Installation and Wiring
For details of the each function, refer to the electronic manual. M
anuals can be
downloaded or viewed at the following URL.
Functional
Enhancement
http://www.yokogawa.com/ns/ut/im/
«Standard Code Model»
• AuthorisedRepresentativeintheEEA
Yokogawa EuropeBV. (Address:Euroweg2,3825HDAmersfoort,The
Netherlands)istheAuthorisedRepresentativeofYokogawaElectric Corporation
forthisProductintheEEA.
• Printed Manuals
Model Description
UP35A/UP32AProgramControllerOperationGuide«StandardCodeModel» IM05P02D41-11EN
UP35AProgramControllerOperationGuide«DetailedCodeModel» IM05P02D41-15EN
PrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11EN
• ElectronicManuals
Youcandownloadthelatestmanualsfromthefollowingwebsite:
URL:http://www.yokogawa.com/ns/ut/im/
Model Description
UP35A/UP32AProgramControllerOperationGuide«StandardCodeModel» IM05P02D41-11EN
UP35AProgramControllerOperationGuide«DetailedCodeModel» IM05P02D41-15EN
UP35A/UP32AProgramControllerUser’sManual IM05P02D41-01EN
UTAdvancedSeriesCommunicationInterface(RS-485,Ethernet)User’sManual IM05P07A01-01EN
UTAdvancedSeriesCommunicationInterface(OpenNetwork)User’sManual IM05P07A01-02EN
LL50AParameterSettingSoftwareInstallationManual IM05P05A01-01EN
LL50AParameterSettingSoftwareUser’sManual IM05P05A01-02EN
PrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11EN
• GeneralSpecication
Model Description
UP35A/UP32AProgramController GS05P02D41-01EN
LL50AParameterSettingSoftware GS05P05A01-01EN
* Thelasttwocharactersofthemanualnumberandgeneralspecificationnumberindicatethe
languageinwhichthemanualiswritten.