DESCRIPTION
YORK has combined the latest concepts in modern technology
with time-proven quality standards to design a split-system
heat pump to meet the demands of the energy-and
quality-conscious commercial market.
Both the outdoor and indoor units are completely piped and
wired at the factory. Only the interconnecting liquid and vapor
lines are required to complete the refrigerant circuit. Every unit
is dehydrated, evacuated, leak tested and pressure tested
before being pressurized with a holding charge of
refrigerant-22 for shipment and/or storage. The compressor,
the fan motors and the controls are functionally tested after the
units are fabricated to assure a reliable start-up and years of
dependable operation.
These units have been tested by Underwriters’ Laboratories
and will be shipped with UL and CUL labels.
OUTDOOR UNIT
Every outdoor unit includes a heavy-duty compressor with a
crankcase heater, line break overload protection, a suction line
accumulator with a fusible plug, a 4-way reversing valve with
a 24-volt solenoid, outdoor fan motor(s) with inherent
protection, and a copper tube/aluminum fin coil that is
positioned vertically for better drainage of the water that will
condense on it during the heating cycle.
They also include a filter-drier, an expansion valve and a
distributor that are only used during the heating cycle plus a
check valve to provide the proper flow of refrigerant through the
unit during both the cooling and heating cycles.
To eliminate the costly cabinet deterioration problems usually
associated with outdoor equipment, all sheet metal parts are
constructed of commercial grade (G90) galvanized steel. After
fabrication, each part is thoroughly cleaned to remove any
grease or dirt from its surfaces. The parts that will be exposed
to the weather are then coated with a "desert sand" powder
paint to assure a quality finish for many years. This coating
system has passed the 750 hour, salt spray test per ASTM
Standard B117. To assist in servicing, the high and low pressure
service connections are exterior to the cabinet, allowing simple
access.
The fan guards are vinyl-coated to provide additional rust
protection. An optional decorative coil guard is available to
protect the coil on the outdoor unit.
INDOOR UNIT
Every indoor unit includes a well-insulated cabinet, a copper
tube/aluminum fin coil, 1" throwaway filters, a centrifugal
blower, a blower motor, adjustable drive components, a blower
motor contactor and a small holding charge of refrigerant-22.
They also include a filter-drier, an expansion valve and a
distributor that are only used during the cooling cycle plus a
check valve to provide the proper flow of refrigerant through the
coil during both the cooling and heating cycles.
The units are shipped in the vertical position ready for field
installation. For horizontal installation, interchange the solid
bottom panel and the return air duct flange on the front of the
unit.
515.41-TG1Y (498)
SPLIT-SYSTEM
HEAT PUMPS
50 AND 60 HZ
E2FB090/E1FB120/F3EH090 & 120
7-1/2 & 10 NOMINAL TONS (60 HZ)
7 & 9 NOMINAL TONS (50 HZ)
(9.0 - 9.2 EER)
®
208/230
VOLT ONLY
208/230/460
VOLT ONLY
Question and Answer IconNeed help?

Do you have a question about the York E2FB090 and is the answer not in the manual?

York E2FB090 Specifications

General IconGeneral
BrandYork
ModelE2FB090
CategoryAir Conditioner
LanguageEnglish

Summary

DESCRIPTION

General Description

Overview of YORK's split-system heat pump technology and manufacturing standards for commercial markets.

Outdoor Unit Features

Details heavy-duty compressor, crankcase heater, overload protection, and reversing valve.

Indoor Unit Features

Describes insulated cabinet, copper tube/aluminum fin coil, centrifugal blower, motor, and filter-drier.

APPLICATION FLEXIBILITY

Outdoor Unit Installation

Discusses lightweight nature, lifting methods, sound levels, and condensate management for outdoor units.

Indoor Unit Installation

Details single cabinet design, vertical/horizontal positioning, and accessory usage for indoor units.

ARI RATINGS - COOLING, HEATING AND SOUND

System Application Data

Provides air temperature parameters for indoor and outdoor coils during cooling and heating cycles.

Refrigerant Piping Limitations

Specifies maximum vertical rise, total length, and other limitations for refrigerant piping installation.

System Flexibility

Explains coil circuity for performance and subcooling, allowing flexible unit mounting and piping configurations.

COOLING CAPACITIES

Cooling Capacity Data

Presents detailed cooling capacities (Total, Sensible) and power input (KW) for various temperature conditions.

HEATING CAPACITIES

Heat Pump Heating Capacities

Lists heating capacities (MBH, KW) for heat pump operation at various outdoor and indoor air temperatures.

Electric Heat Accessory Capacities

Details nominal heating capacities (KW, MBH) for electric heat accessory models at different voltage inputs.

BLOWER MOTOR AND DRIVE DATA

Blower Motor and Drive Specifications

Provides motor HP, blower HP, pulley dimensions, belt designation, and RPM ranges for blower operation.

Supply Air Blower Performance

Presents performance data (CFM, ESP, BHP, KW) for various RPMs and static pressures for the supply air blower.

STATIC RESISTANCES FOR UNIT ACCESSORIES

Accessory Static Resistances

Lists static pressure resistance (IWG) for electric heat, supply air plenum, and return air grille accessories.

Field-Installed Accessories

Describes electric heaters, supply air plenums, return air grilles, base sections, and thermostat options.

UNIT DIMENSIONS & CLEARANCES - OUTDOOR UNITS

Outdoor Unit Clearances

Specifies minimum required clearances for overhead, front, sides, and rear of the outdoor unit for installation.

Outdoor Unit Center of Gravity

Provides approximate center of gravity dimensions (A, B, C, D) for different outdoor unit sizes.

UNIT DIMENSIONS & CLEARANCES - INDOOR UNITS

Indoor Unit Clearances and Accessory Dimensions

Details minimum clearances for indoor units and shows added dimensions for electric heaters, plenums, and bases.

Field Wiring and Connections

Outlines wiring terminals for indoor/outdoor units, thermostat connections, and power supply requirements.

ACCESSORY DIMENSIONS

Electric Heater Dimensions

Provides dimensions for the electric heater accessory, including wiring harness and power supply access openings.

Supply Air Plenum Dimensions

Shows dimensions for the supply air plenum, including knockout locations for power and control wiring.

Return Air Grille Dimensions

Provides dimensions for the return air grille accessory.

Base Section Dimensions

Shows dimensions for the base accessory, used to raise the indoor unit.

PHYSICAL DATA (OUTDOOR UNIT)

PHYSICAL DATA (INDOOR UNIT)

PHYSICAL DATA - ELECTRIC HEAT ACCESSORIES

ELECTRICAL DATA

Outdoor Unit Electrical Data

Provides electrical specifications for outdoor units, including compressor, fan motor, power supply, and wiring.

Indoor Unit Electrical Data

Details electrical data for indoor units, including blower motor, electric heat, power supply, and wiring.

Control Wire Sizing

Specifies wire size requirements based on circuit length for control wiring between indoor and outdoor units.