251933-YTG-B-0806
34 Unitary Products Group
XP036-060 Side Duct Application
XP036 (3.0 Ton)-Side Duct
Air Flow
(CFM)
Available External Static Pressure - IWG
1
0.2 0.3 0.4 0.5 0.6 0.7
RPM W BHP RPM W BHP RPM W BHP RPM W BHP RPM W BHP RPM W BHP
800 - - - 630 235 0.25 677 306 0.33 730 395 0.42 773 434 0.47 815 470 0.51
900 602 192 0.20 657 292 0.31 704 360 0.39 756 444 0.48 798 484 0.52 840 519 0.56
1000 631 255 0.27 684 349 0.37 731 414 0.45 789 527 0.57 831 567 0.61 874 602 0.65
1100 660 318 0.33 712 406 0.43 757 469 0.51 811 559 0.60 854 599 0.64
896 634 0.68
1200 689 380 0.40 739 462 0.50 791 548 0.59 833 592 0.63 876 632 0.68
918 667 0.72
1300 718 443 0.47 772 539 0.58 813 584 0.63 855 628 0.67
898 668 0.72 940 703 0.75
1400 747 505 0.54 795 579 0.62 836 624 0.67 878 668 0.72
920 708 0.76 963 744 0.80
1500 779 578 0.62 819 624 0.67 860 669 0.72
902 713 0.77 944 753 0.81 987 789 0.85
1600 804 629 0.67 844 675 0.72
885 720 0.77 927 764 0.82 970 804 0.86 1013 839 0.90
1700 831 685 0.74 871 731 0.78 913 777 0.83 955 820 0.88 997 861 0.92 1040 869 0.96
1800 860 748 0.80
901 794 0.85 942 839 0.90 984 883 0.95 1026 923 0.99 1069 958 1.03
1900
891 817 0.88 931 862 0.92 973 908 0.97 1015 951 1.02 1057 992 1.06 1100 1027 1.10
2000
924 891 0.96 964 937 1.01 1005 982 1.05 1047 1026 1.10 1090 1066 1.14 1133 1102 1.18
Air Flow
(CFM)
Available External Static Pressure - IWG
1
1. Blower performance includes 1" filters. See STATIC RESISTANCE table for additional applications.
0.8 0.9 1.0 1.1 1.2 1.3
RPM W BHP RPM W BHP RPM W BHP RPM W BHP RPM W BHP RPM W BHP
800 858 499 0.54
904 532 0.57 952 564 0.61 994 571 0.62 1035 563 0.60 1075 543 0.59
900
884 548 0.59 928 579 0.62 975 605 0.65 1017 610 0.66 1058 600 0.64 1097 577 0.62
1000
917 631 0.68 959 651 0.70 1001 660 0.71 1040 658 0.71 1081 642 0.69 1119 611 0.66
1100
939 663 0.71 981 683 0.73 1023 692 0.74 1064 690 0.74 1103 674 0.72 1141 643 0.69
1200 961 696 0.75 1003 716 0.77 1045 725 0.78 1086 723 0.78 1125 707 0.76 1163 676 0.73
1300
983 732 0.79 1025 752 0.81 1067 761 0.82 1108 759 0.81 1147 743 0.80 1185 712 0.76
1400
1006 772 0.83 1048 792 0.85 1090 801 0.86 1130 799 0.86 1170 783 0.84 – – –
1500
1030 817 0.88 1072 837 0.90 1114 847 0.91 1154 844 0.91 1194 829 0.89 – – –
1600
1055 868 0.93 1098 888 0.95 1139 897 0.96 1180 895 0.96 – – – – – –
1700
1083 924 0.99 1125 944 1.01 1166 954 1.02 – – – – – – – – –
1800 1112 987 1.06 1154 1007 1.08 – – – – – – – – – – – –
1900
1142 1055 1.13 1185 1075 1.15 – – – – – – – – – – – –
2000
1175 1130 1.21 – – – – – – – – – – – – – – –
Factory Installed AK74 blower sheave and A39 belt.
AK61 blower sheave and A36 belt - Field installation required.
http://www.rezine.ne
Page 36