251933-YTG-B-0806
48 Unitary Products Group
060
(5.0)
208-1-60 29.0 145.0 45.0 2.3 7.6 10.0
None -- -- 55.9 70
E05 4.0 19.2 55.9 70
E07 5.6 26.9 55.9 70
E10 8.0 38.5 70.1 80
E15 11.9 57.2 93.5 100
E20 15.9 76.4 117.6 125
E30 22.2 106.7 155.4 175
230-1-60 29.0 145.0 45.0 2.3 7.6 10.0
None -- -- 55.9 70
E05 5.3 22.1 55.9 70
E07 7.5 31.3 61.1 80
E10 10.6 44.2 77.2 80
E15 15.9 66.3 104.8 110
E20 21.2 88.3 132.4 150
E30 29.6 123.3 176.2 200
208-3-60 17.3 123.0 27.5 2.3 5.2 10.0
None -- -- 39.5 50
E05 4.0 11.1 39.5 50
E07 5.6 15.5 39.5 50
E10 8.0 22.2 46.8 50
E15 11.9 33.0 60.3 70
E20 15.9 44.1 74.2 80
E30 22.2 61.6 96.0 100
230-3-60 17.3 123.0 27.5 2.3 5.2 10.0
None -- -- 39.5 50
E05 5.3 12.7 39.5 50
E07 7.5 18.0 41.6 50
E10 10.6 25.5 50.9 60
E15 15.9 38.2 66.8 70
E20 21.2 51.0 82.7 90
E30 29.6 71.2 108.0 110
460-3-60 9.6 70.0 15.0 1.3 2.6 5.0
None -- -- 20.9 30
E07 6.8 8.2 20.9 30
E10 10.1 12.1 24.7 30
E15 13.6 16.4 29.9 30
E20 19.5 23.5 38.8 40
E30 28.8 34.6 52.8 60
575-3-60 7.5 53.0 11.7 1.3 2.0 4.0
None -- -- 16.4 20
E10 10.6 10.2 20.2 25
E15 15.9 15.3 26.6 30
E20 21.2 20.4 33.0 35
E30 30.4 29.3 44.1 45
1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.
ZJ036-060 (Continued)
Size
(Tons)
Volt
Compressors
(each)
OD Fan
Motors
(each)
Supply
Blower
Motor
Pwr
Conv
Outlet
Electric Heat Option
MCA
1
(Amps)
Max Fuse
2
/
Breaker
3
Size
(Amps)
RLA LRA MCC FLA FLA FLA Model kW Amps
http://www.rezine.ne
t
Page 50