Page 25
- NONE: Means that there aren't any switch or potentiometer installed on
the brake.
12QUICK INVERSION
- NONE The quick inversion function is not managed.
- TIMED The quick inversion function is timed.
- BELLY The quick inversion function is managed but not timed.
13AUX VOLTAGE #1
- % this parameter permits to program the supply voltage of the
main contactor coil and the electromechanical brake.
14PERFORMANCE
- OPTION #1 Set of parameter which determines a "Low Performance".
- OPTION #2 Set of parameter which determines a "High Performance".
SOTTOMENU' "ADJUSTMENT"
1 SET POT BRK MIN: records the minimum value of braking pedal potentiometer
when the braking pedal switch is closed; the procedure is
similar to the "Program Vacc" function (see chapter 5.4). This
procedure must be carried out only if the "Pedal braking"
option is programmed as "Analog".
2 SET POT BRK MAX: records the maximum value of braking pedal potentiometer
when the braking pedal is fully pressed; the procedure is simi-
lar to the "Program Vacc" function (see chapter 5.4). This
procedure must be carried out only if the "Pedal braking"
option is programmed as "Analog".
3 MOTOR OVERTEMP: if the temperature of the motor is higher than the specified
value, a motor temperature warning occurs.
4 SET MOT TEMP: fine adjustment of the temperature of the motor measured by
the controller.
5 SET BATTERY TYPE: selects the nominal battery voltage.
6 ADJUST BATTERY: fine adjustment of the battery voltage measured by the
controller.
7 THROTTLE 0 ZONE: establishes a deadband in the accelerator input curve (see
also curve below).
8 THROTTLE X POINT: These parameter change the characteristic of the accelerator
input curve.