11AUX VOLTAGE #1
- % this parameter permits to program the supply voltage of the
main contactor coil and the electromechanical brake.
12PERFORMANCE
- OPTION #1 Set of parameter which determines a "Low Performance".
- OPTION #2 Set of parameter which determines a "High Performance".
13VALVE 1 TYPE
- OPTION #1 Electrovalve n°1 is an On/Off valve.
- OPTION #2 Electrovalve n°1 is a proportional valve.
14VALVE 2 TYPE
- OPTION #1 Electrovalve n°2 is an On/Off valve.
- OPTION #2 Electrovalve n°2 is a proportional valve.
SOTTOMENU' "ADJUSTMENT"
1 MIN LIFT: records the minimum value of the lifting proportional
potentiometer when the "Lift" switch is closed;
2 MAX LIFT: records the maximum value of the lifting proportional
potentiometer.
3 MIN LOWER: records the minimum value of the lowering proportional
potentiometer when the "Lower" switch is closed;
4 MAX LOWER: records the maximum value of the lowering proportional
potentiometer.
5 MOTOR OVERTEMP: if the temperature of the motor is higher than the specified
value, a motor temperature warning occurs.
6 SET MOT TEMP: fine adjustment of the temperature of the motor measured by
the controller.
7 SET BATTERY TYPE: selects the nominal battery voltage;
8 ADJUST BATTERY: fine adjustment of the battery voltage measured by the
controller.
9 THROTTLE 0 ZONE: establishes a deadband in the accelerator input curve (see
also curve below).
10 THROTTLE X POINT: These parameter change the characteristic of the accelerator
input curve.