AFCZP0BC – COMBIACX & ACEX - User Manual Page - 21/81
is strongly suggested to connect to truck frame all the parts of the
truck which can be touched by the operator, who is most of the time
the source of ESD.
4.5 Various suggestions
Never combine SCR low frequency choppers with COMBIACX / ACEX modules.
The filter capacitors contained in the COMBIACX / ACEX module would change the
SCR chopper operation and subject to excessive workload. If it is necessary to use
two or more control units, like the chopper should be of the Zapimos family.
During battery recharge, the COMBIACX / ACEX must be completely disconnected
from the battery. Beside changing the charging current seen by the battery charger,
the module can be damaged by higher than normal voltages supplied via the
charger.