Page - 42/81 AFCZP0BC- COMBIACX & ACEX - User Manual
19) EB VOLTAGE RED
%. This parameter stores the PWM value applied to EB coil after the first
second of the output activation. It is expressed in percentage of the voltage
applied during the first second (defined by the previous parameter).
20) PWM EV2
%. This parameter stores the PWM value applied to the EV2 coil. It is
expressed in percentage of battery voltage.
21) PWM EV3
%. This parameter stores the PWM value applied to the EV3 coil. It is
expressed in percentage of battery voltage.