4 OPERATIONAL FEATURES
Mhyrio Flash has been designed to work on a CAN-BUS system. So, it follows
the commands received by CAN communication and broadcast the input status
and the encoder counting on the CAN.
The 8 proportional valves are separated in 4 groups used for 4 different
functions. Only one valve of the group can be active.
It is possible to activate more function at the same time. These can be:
- function 1-2-3
- function 1-2-4
3 and 4 cannot be activate at the same time.
FUNCTION1 is related to EVP1 and 2 (outputs G8, G7); typically this
function is lifting-lowering.
FUNCTION2 is related to EVP3 and 4 (outputs G6, G5); typically this
function is reach in/out.
FUNCTION3 is related to EVP5 and 6 (outputs G4, G3); typically this
function is tilting fw/rev.
FUNCTION4 is related to EVP7 and 8 (outputs G2, G1); typically this
function is shifting right/left.