Page - 22/36 ADPZP0CC - MHYRIO FLASH CONTROLLER - User Manual
7.4 Description of programmable functions (options)
The options can be set on the “SET OPTIONS” Menu.
Function Option Meaning
EV2 TYPE OPTION #1
It sets EV2 to ON-OFF valve type.
OPTION #2
It sets EV2 to PROPORTIONAL valve type.
EV1 TYPE OPTION #1
It sets EV1 to ON-OFF valve type.
OPTION #2
It sets EV1 to PROPORTIONAL valve type.
EV3 TYPE OPTION #1
It sets EV3 to ON-OFF valve type.
OPTION #2
It sets EV3 to PROPORTIONAL valve type.
EV4 TYPE OPTION #1
It sets EV4 to ON-OFF valve type.
OPTION #2
It sets EV4 to PROPORTIONAL valve type.
EV5 TYPE OPTION #1
It sets EV5 to ON-OFF valve type.
OPTION #2
It sets EV5 to PROPORTIONAL valve type.
EV6 TYPE OPTION #1
It sets EV6 to ON-OFF valve type.
OPTION #2
It sets EV6 to PROPORTIONAL valve type.
EV7 TYPE OPTION #1
It sets EV7 to ON-OFF valve type.
OPTION #2
It sets EV7 to PROPORTIONAL valve type.
EV8 TYPE OPTION #1
It sets EV8 to ON-OFF valve type.
OPTION #2
It sets EV8 to PROPORTIONAL valve type.
SET Battery Type 12/24/36/
/48/60/72/
/80/96/120V
This parameter sets the battery nominal
voltage, that is the key input voltage
(MHYRIO FLASH supply)
SET Voltage 12/24/36/
/48/60/72/
/80/96/120V
This parameter sets the on/off valves coil
nominal voltage
HOUR COUNTER Running
Mhyrio Flash internal hourcounter is
incremented when one function is active
Key on
Mhyrio Flash internal hourcounter is always
incremented when Mhyrio Flash is supplied