Page - 36/36 ADPZP0CC - MHYRIO FLASH CONTROLLER - User Manual
10 PERIODIC MAINTENANCE TO BE
REPEATED AT TIMES INDICATED
Check the wear and condition of the Contactors’ moving and fixed contacts.
Electrical Contacts should be checked every; ...................................... 3 MONTHS
Check the Foot pedal or Tiller microswitch. Using a suitable test meter, confirm
that there is no electrical resistance between the contacts by measuring the volt
drop between the terminals. Switches should operate with a firm click sound.
Microswitches should be checked every; ............................................. 3 MONTHS
Check the Battery cables, cables to the controller, and cables to the motor.
Ensure the insulation is sound and the connections are tight. Cables should be
checked every;...................................................................................... 3 MONTHS
Check the mechanical operation of the pedal or tiller. Are the return springs ok.
Do the potentiometers wind up to their full or programmed level. Check every;
.............................................................................................................. 3 MONTHS
Check the mechanical operation of the Contactor(s). Moving contacts should be
free to move without restriction. Check every;...................................... 3 MONTHS
Checks should be carried out by qualified personnel only and any replacement
parts used should be original. Beware of NON ORIGINAL PARTS. The
installation of this electronic controller should be made according to the diagrams
included in this Manual. Any variations or special requirements should be made
after consulting a Zapi Agent.
The supplier is not responsible for any problem that arises from wiring methods
that differs from information included in this Manual. During periodic checks, if a
technician finds any situation that could cause damage or compromise safety, the
matter should be bought to the attention of a Zapi Agent immediately. The Agent
will then take the decision regarding operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.