Page 53
8) HYD SPEED FINE = Fine hydrodrive speed (a value from 0 to 10% Vbatt is added
to the coarse speed value). The speed is given by:
motor voltage = [(coarse speed) x 10 + (fine speed)] x Vbatt /100
The interval of values ranges from 0 to total conduction.
9) HYDRO COMPENS = Compensation in current for hydrodrive request.
10) CREEP SPEED = Defines the minimum value of voltage applied to the motor with
running request active. Allows a more immediate response at start up.
11) WEAK DROPOUT = Threshold of current for opening the weakening contactor (if
programmed as such and not as bypass, in which case the output threshold is fixed
and not programmable).
12) HYDRO TIME = Hydrodrive delay time. If set at 0, there is no delay; thus the
hydrodrive input can be handled as a 5th speed.
13) 1ST SPEED COARSE = Speed no. 1, coarse adjustment.
14) 1ST SPEED FINE = Speed no. 1, fine adjustment.
15) 1ST SPEED COMP. = Compensation speed no.1.
16) 2ND SPEED COARSE = Speed no. 2, coarse adjustment.
17) 2ND SPEED FINE = Speed no. 2, fine adjustment.
18) 2ND SPEED COMP. = Compensation speed no.2.
19) 3RD SPEED COARSE = Speed no. 3, coarse adjustment.
20) 3RD SPEED FINE = Speed no. 3, fine adjustment.
21) 3RD SPEED COMP. = Compensation speed no.3.
22) 4TH SPEED COARSE = Speed no. 4, coarse adjustment.
23) 4TH SPEED FINE = Speed no. 4, fine adjustment.
24) 4TH SPEED COMP. = Compensation speed no.4.
25) MIN. VALVE VOLT. = Minimum voltage applied on the proportional solenoid valve.
26) MAX. VALVE VOLT. = Maximum voltage applied on the proportional solenoid valve.
H2B standard lifting