8
English
Integrated energy meter
Parameter Value
Certification MID Class B
Harmonized Standard EN 50470 -1, - 3
Notified Body Justervesenet (0431) / NMi Certin (0122)
Rated Voltage 3 × 230/400 V
Rated Current 0.25-5 (32) A
Optical Test Output (must be activated in the app) 10000 imp/kWh
Connectivity
Protocol Supported standards
4G LTE Cat M1
Wi-Fi 802.11b/g/n (2.4 GHz)
Bluetooth Bluetooth v5.1 (BR/EDR/BLE)
Powerline (PLC) HomePlug Green PHY, 10 Mbit/s
Plug and charge Hardware support for ISO15118
RFID ISO/IEC 14443 A (Type A, 13.56 MHz)
ISO/IEC 15693 (Mifare classic, 13.56 MHz)
Integrated RCCB
Parameter Symbol Min Typ Max Unit
Residual operating current IΔn 0.03 A
Operating characteristics Type B
Making and breaking capacity Im 500 A
Residual making and breaking
capacity
IΔm 500 A
Rated conditional short-circuit
current
Inc 3 kA
Rated conditional residual short-
circuit current
IΔc 3 kA
Integrated circuit breaker
Parameter Symbol Min Typ Max Unit
Manufacturer and part number Lovato P1 MB 3P C40
Rated current In 40 A
Curve C
Nominal short-circuit breaking
capacity
Icn 10 kA
For CE documentation please see zaptec.com/CE-documentation