Operation manual of ZBL-R800, ZBL-R630, ZBL-C310A
Hotline: (86)010-51290405 Fax: (86)010-51290406
56
3.5.2 Introduction of main menu
3.5.2.1 Object No.
Object No. should correspond one by one with tested object. Every
object No. can store up to 13 row × 18 columns, a total of 234
potential values of measuring points.
Object No. can increase automatically. After measurement of a survey
area is complete, go back to main menu, then the object No. will
increase by 1 automatically.
When changing object No. manually, select the “Obj. No.” menu, and
then operate as follows:
1. Pressing ENTERto enter into object No. adjustment state,
at that time, cursor will occur at the last digit of No.
2. Pressing aorbto adjust this digit and pressing _
or`to select other data bits.
The number adjustment can add or subtract value, the
maximum is 999.
3. Pressing MENUto go back to menu selection state and
continuing other menu operation.
4. PressingBACKto go back to previous state.
3.5.2.2 Test method
Rust test is divided into single-electrode test and double-electrode
test.
Pressing aorbin main menu to move cursor to “Method
option, pressingENTERto enter into test method selection menu as
shown in figure3-40, “
”stays on the current test method for
reference. Pressing aorb key to select test method, and
pressing ENTER or SAVEto select certain test method and