Operations
Calibrate the Printer
76
P1009874-001 Xi4 User Guide 3/12/09
Sensor Profile
Calibration
The printer auto-calibrates and prints
a media sensor profile.
Select the SENSOR PROFILE
option on the control panel. See Print
Sensor Profile on page 100 for
instructions.
Media and Ribbon
Sensor Sensitivity
Calibration
One of the most common adjustments
to printer settings. The printer resets
the sensitivity of the sensors to detect
correctly the media and ribbon that
you are using. If you change the type
of ribbon and/or media, you might
need to reset the sensitivity of the
media and ribbon sensors. When the
sensors are at their new sensitivity, the
printer performs an auto-calibration.
Select the
MEDIA AND RIBBON
CALIBRATE
option on the control
panel. See Calibrate Media and
Ribbon Sensor Sensitivity on page 101
for instructions.
Table 8 • Types of Calibration (Continued)
Type of Calibration Description When/How It Occurs