17
Be sure to read the installation and
operating manual before installing.
This allows you to protect yourself
Scope of delivery
Calculator for heat meters multidata WR3
Sealing material
Wall holder with mounting accessories (in the lower housing)
Installation and operating instructions, declaration of conformity
and prevent damage. Check the
contents of the packing before
installation to be complete.
Technical data multidata WR3
Temperature range
°C 0 - 150
Temperature dierence
range
K 3 - 120
Display
LCD multifunctional display, 8-digit plus
special characters
Display unit
Standard: MWh
Optional: kWh, MJ, GJ
Volume pulse generator can
be connected
Reed switch, open collector or active
Input frequency:
max. 1 Hz for passive transmitters,
max. 100 Hz for active transmitters
Temperature sensor
connection
PT500
Max. Sensor cable length
2-wire
m 12.5
Max. sensor cable length
4-wire
m 20
Data interfaces
As standard: Optical data interface,
2 programmable pulse outputs/inputs
optional: M-Bus, RS 485, RS 232
Ambient temperature
°C 5 - 55
Power supply
1
Lithium battery 3.6 V
Optional: Via M-Bus level converter or
plug-in power supply (output: 24 V DC)
Battery lifespan
At least 5 years + 1 year reserve,
optional 10 years + 1 year reserve
Protection class
IP 54 / IP 65
Mechanical/
electromagnetic class
M1 / E1
Measuring accuracy
In accordance with DIN EN 1434-1
Measuring cycle time
Standard: 30 seconds
(10 seconds when operating button is
pressed)
For versions with M-Bus interface: 10 seconds
(
1
) Possibility for battery replacement is depending on the country, please check the relevant