Hydraulic syste
m
Indication of low oil temperature
Hydraulic pump
Control elements placement
The system consists of the inner and outer circuit.
The source of pressurized oil is a gear pump.
Oil is drawn from the common filling of the gearbox and
final drive housing.
F_02_112a
If the temperature of gear oil is lower than 20°C,
the signal lamp of the pushing filter of gearbox
distributor (1) is flashing.
When the temperature of gear oil is higher than 20°C,
the signal lamp (1) stops glowing.
If the signal lamp (1) is flashing, it is not
recommended to use outer circuits of hydraulics.
The hydraulic pump cannot be disengaged. When the
engine is running, the pump is in operation.
The pressure generated in the hydraulic system by the
hydraulic pump is limited by a relief valve to 20 MPa.
Pump type Delivered quantity
GHD0 32/12,6L 85 l/min
F_02_113a
Control panel is placed on the right rear mudguard.
1. Electrohydraulics control
2. External hydraulic circuit control
FHD14N042
HYDRAULIC SYSTEM
8989