Outer hydraulic circuit
Connecting and disconnecting quick-couplers
When connecting and disconnecting the quick-couplers pay increased attention with regard to
the residual oil that remains in the socket or on the plug of the quick-coupler. For environmental
reasons after every disconnection of quick-couplers this residual oil must be removed with any
textile material.
Quick-couplings with drip collection
External hydraulic circuit controls
The outer circuit supplies pressurized oil to hydraulic
implements connected to the outer outlets of the hydraulic
system terminated with quick-couplers.
The sockets of the rear (A) as well as front (B) quick-
couplers have the inner diameter of 12.5 mm and comply
with the international ISO 5675 standard.
FHD14N049
On request, dripping system for holding leakage oil can be
installed. Regularly check whether the tank is not full;
dispose of the oil in an environment-friendly way.
FHD14N060
1. system activation button
2. joystick activation or front outlets switch button
3. joystick
4. applicable hydraulic circuit controls
5. system status controls
6. pivoting selectors for setting the disengagement of
applicable hydraulic circuit depending on time
7. pivoting selectors for setting the flow of oil of an
applicable hydraulic circuit
FHD14N051