It is used to set the Wiegand input and output parameters.
Wiegand Format: Its value can be 26 bits, 34 bits, 36 bits, 37 bits, and 50
bits.
Wiegand Bits: The number ofbits of the Wiegand data.
ID Type: Select between the User ID and card number.
Various Common Wiegand Format Description:
Wiegand Format
Description
Wiegand26
ECCCCCCCCCCCCCCCCCCCCCCCCO
It consists of 26 bits of binary code. The 1
st
bit is the even
parity bit of the 2
nd
to 13
th
bits, while the 26
th
bit is the
odd parity bit of the 14
th
to 25
th
bits. The 2
nd
to 25
th
bits
are the card numbers.
Wiegand26a
ESSSSSSSSCCCCCCCCCCCCCCCCO
It consists of 26 bits of binary code. The 1
st
bit is the even
parity bit of the 2
nd
to 13
th
bits, while the 26
th
bit is the
odd parity bit of the 14
th
to 25
th
bits. The 2
nd
to 9
th
bits are
the site codes, while the 10
th
to 25
th
bits are the card
numbers.
Wiegand34
ECCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCO
It consists of 34 bits of binary code. The 1
st
bit is the even
parity bit of the 2
nd
to 17
th
bits, while the 34
th
bit is the
odd parity bit of the 18
th
to 33
rd
bits. The 2
nd
to 25
th
bits
are the card numbers.

Other manuals for ZKTeco KF1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZKTeco KF1000 Series and is the answer not in the manual?

ZKTeco KF1000 Series Specifications

General IconGeneral
BrandZKTeco
ModelKF1000 Series
CategoryIP Access Controllers
LanguageEnglish

Related product manuals