Zodiac DuoClear - Troubleshooting: Add Salt Indicator; Add Salt Light Diagnosis; Flickering Indicator Lights

Zodiac DuoClear
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Add Salt Light is On
Issaltlevel4000ppmorhigher?
YES
NO
Addsaltaccordingtochart
inOwner’sManual.
Ignorelighttillwaterwarmsup.
OR
Raisesaltleveltocompensate
forcoldwater.
TesttouchpadPCB.
(see Touch Pad PCB pg. 14)
Iswaterbelow65deg.F?
YES NO
Cellisnearingendoflife.
Replacecell.
(see Cell pg. 13)
Only 1 or 2 Output Lights and/or Add Salt and/or No Flow Lights are Flickering
Issaltlevel4000ppmorhigher?
YES
NO
Chlorinatoriswired110V.Havequalified
electricianwirechlorinatorto220V.
Addsaltaccordingtochart
inOwner’sManual.
Cellisnearingendoflife.
Replacecell.(seeCellpg.13)