5
Testing the Power Path
1. Turn off power supply.
2. Remove 4 screws to remove cover and hang cover from venting with “S” hooks provided in kit.
Do not disconnect ribbon wire.
3. Turn on power supply.
4. Use multimeter set on AC volts up to at least 250 VAC to test between L & M (All results should
be +/- 10%).
Results=220V?
YES
NO
Unitreceivingpower–continuetesting.
Havequalifiedelectricianrewirechlorinatorto
220Vordetermine
whynovoltage.
Resetorreplace
circuitbreaker.
(see Circuit Breaker pg. 4)
Transformerreceivingpower
circuitbreakerOK(continuetesting).
6.TestbetweenN&K=220V?
YES NO
7.TestbetweenH&FandH&D.
Resultsshouldbeasprinted
ontransformer(26.5V).
BothtestsreadOK?
YES NO
Transformerisgood.
Replacetransformer.
(see Transformer pg. 9)
A B C D E F G H I J N K L M