12
Chlorine Reading is Too High
Dotheoutputlightsgoupanddown?
YES
NO
Reduceoutputsetting.
ChecktouchpadPCB.
(see Touch Pad PCB pg. 14)
ReplacepowerPCB.
(see Touch Pad PCB pg. 14)
Reducepumpruntime.
CheckpH.
(pertestkitinstructions)
Checkcalciumhardness.
(pertestkitinstructions)
Cleancellmanually.
(see pg. 13)
Calcium Build-up on Cell
Ischlorinatorreversingpolarityproperly?
Pressandholdservicebutton
(located1”totherightoftheON/OFFswitch
andtheNature2Resetswitch)
tospeedupthereversingprocess.
(see Reversing Polarity pg. 13)
YES
NO
ChecktouchpadPCB.
(see Power PCB pg. 16)
Note: New plaster pools will have a
continuous demand for acid for 6 months
or more.
High pH conditions and/or high calcium
hardness levels will make scale build-up more
likely. Maintain a pH between 7.2 and 7.6.