Output Lights Will Not Go To 100%
Issaltlevel4000ppmorhigher?
YES
NO
Addsaltaccordingtochart
inOwner’sManual.
Checkthereis220Vincomingpower.
YES NO
Iswatertemperaturebelow65˚F?
YES NO
Addsalttocompensate.
Cellmaybenearingtheendofitslife.Check
cellage,runtime&outputsetting.
Replacecell. (see Cell pg. 13)
Ifunitislessthan1yearoldcheck
thefollowing:
ChecktouchpadPCB.
(see Touch Pad PCB pg. 14)
ReplacepowerPCB.
(see Power PCB pg. 16)
Havequalifiedelectrician
rewirechlorinatorto220V.