Chapter3Notication
PossibleCauses
Themodulehasbeenreset
HandlingProcedure
None
3.710013Modulestatuserror
NoticationProperty
lNoticationCode:10013
lNoticationInformation:Theopposite-endboardstatusisabnormal.Thestatusis
obtainedbyreadingsignalsonthesignalcableviabottom-layerBSP .Suchabnormal
statusseldomoccurs,andsuchexceptionisoftenusedbyR&Dpersonneltolocate
thefault.
lNoticationType:EquipmentAlarm
Sub-codeDescription
lSub-code1:Themoduleispowereddown
lSub-code2:Generalmodulefault
EffectontheSystem
Themodulestatusisabnormal.
PossibleCauses
Themodule'sstatusisabnormal.
HandlingProcedure
Extractandinserttheboard.
3.810014Changeovercompleted
NoticationProperty
lNoticationCode:10014
lNoticationInformation:Theactive/standbyRCUBboardchangeoveriscompleted.
lNoticationType:HandlingAlarm
Sub-codeDescription
lSub-code1:InitiateswitchoverinLMT
lSub-code2:Pressbuttonforswitchover
3-5