ZXMWNR8250AlarmandNoticationHandlingReference
lRCU0X30XX
lRTU0X91XX
lRMU0X92XX
lPM0X37XX
2.Turnontheboard'spowersupply.
2.1.21002Boardnotinposition
AlarmProperty
lAlarmCode:1002
lAlarmInformation:Thisalarmisreportedwhentheboardisconguredinthenetwork
managementsystembutisnotinsertedintheactualslot.
lAlarmLevel:Critical
lAlarmType:EquipmentAlarm
Sub-codeDescription
None
EffectontheSystem
Theboardcannotbearanyservice.
PossibleCauses
1.TheboardisconguredinaslotontheLocalMaintenanceT erminal(LMT)butnot
actuallyinsertedinthatslot.
2.TheboardisconguredinaslotontheLMTbutnottightlyinsertedinthatslot.
3.TheboardisconguredinaslotontheLMTbuttheconnectingpartisphysically
damaged.
HandlingProcedure
1.Checkwhethertheboardisinsertedintotheslot.
lIfyes,gotostep2.
lIfno,inserttheboard.
2.Pulloutandplugtheboardintotheslot.Ifthealarmpersists,gotostep3.
3.Replacetheshelf.