ZXMWNR8250AlarmandNoticationHandlingReference
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:Opticalport1ontheRTUBboard;
lSub-code2:Opticalport2ontheRTUBboard.
EffectontheSystem
Thetrafcattheportcorrespondingtothealarmisinterrupted.
PossibleCauses
1.Opticalmoduleisdisabledmanually.
2.TheRTUboardwhereopticalmoduleislocatedisfaulty.
HandlingProcedure
1.Checkwhethertheopticalmoduleisdisabled.
lIfyes,selectTDM>Laserandenabletheopticalmoduleandthealarmiscleared.
lIfno,gotostep2.
2.ReplacetheRTUboardwheretheopticalmoduleisinserted.
2.1.15134239932ODUconfigurationmodeinvalid
AlarmProperty
lAlarmCode:134239932
lAlarmInformation:ThealarmisreportedifODUdoesnotsupporttheissued
congurationmode.
lAlarmLevel:Critical
lAlarmType:EquipmentAlarm
Sub-codeDescription
None
EffectontheSystem
Thetrafccarriedbytheboardisinterrupted.
PossibleCauses
1.TheODUdoesnotsupportthecongurationofthecorrespondingmode.
2.TheODUisfaulty.
HandlingProcedure
ReplacetheODU.
2-12