EasyManua.ls Logo

Zte ZXMW NR8250 - Chapter 2: Alarm Handling; Equipment Alarms

Zte ZXMW NR8250
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter2
Alarm
TableofContents
EquipmentAlarm........................................................................................................2-1
CommunicationAlarm..............................................................................................2-24
HandlingAlarm.........................................................................................................2-60
EnvironmentAlarm...................................................................................................
2-68
QoSAlarm...............................................................................................................2-80
2.1EquipmentAlarm
2.1.11001Boardpoweredoff
AlarmProperty
lAlarmCode:1001
lAlarmInformation:Theboardispoweredoff.
lAlarmLevel:Major
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:Managementpower
lSub-code2:Servicepower
EffectontheSystem
Theboard'scommunicationlinkisbroken,andservicescarriedbytheboardare
interrupted.
PossibleCauses
Theboardispoweredoff.
HandlingProcedure
1.Checktheadditionalinformationofthealarm.
Ifthealarmhasadditionalinformation,checkwhethertheinsertedboardoftheNEis
inconsistentwiththatconguredatOMCB.
Thefollowingliststheboardtypes(Xrepresentsahexadecimalnumber0~F):
2-1
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential