EasyManua.ls Logo

Zte ZXMW NR8250 - 134241728 Loopback State in Ethernet Port; 134243765 1588 Clock PTP Service Setup Failure

Zte ZXMW NR8250
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter2Alarm
2.1.18134241728LoopbackstateinEthernetport
AlarmProperty
lAlarmCode:134241728
lAlarmInformation:ThealarmisreportedwhentheportonRCUB/RTUM/RTUHisin
loopbackstatus.
lAlarmLevel:Major
lAlarmType:EquipmentAlarm
Sub-codeDescription
lSub-code1:RCUBNMSport;
lSub-code2:RCUBGbEport;
lSub-code7:RTUHGbE1port;
lSub-code8:RTUHGbE2port;
lSub-code9:RTUHGbE3port;
lSub-code10:RTUNGbE1port;
lSub-code11:RTUNGbE2port;
lSub-code12:RTUNGbE3port;
lSub-code13:RTUNGbE4port.
EffectontheSystem
Trafcisinterruptedwhenthewirelesslinkportisinloopbackstatus.
PossibleCauses
1.Theloopbackfunctionisenabledfortestormaintenance.
2.Theboardthatreportsthealarmisfaulty.
HandlingProcedure
1.SelectMaintenance>PortLoopback>ETHandcheckwhetherloopbackis
conguredfortestormaintenance.
lIfyes,disabletheloopbackfunctionafterthetestormaintenanceiscompleted.
lIfno,replacethefaultyboard.
2.Ifthealarmpersistsaftertheprecedingstep,replacethefaultyboard.
2.1.191342437651588clockPTPservicesetupfailure
AlarmProperty
lAlarmCode:134243765
lAlarmInformation:Thealarmisreportedifthe1588conversationsetuptimeexceeds
threshold,andthePTPconversationsetupfailureisreported.
lAlarmLevel:Major
2-15
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential

Table of Contents