Chapter3Notication
3.36134317740RMUswitchover
AlarmProperty
lNoticationCode:134317740
lNoticationInformation:ThenoticationisreportedifswitchoverisperformedforRMU
orODU.
lNoticationType:EquipmentAlarm
Sub-codeDescription
lSub-code4:RMUswitchoverfails;
lSub-code5:RMUswitchoversucceeds;
lSub-code6:ODUswitchoverfails;
lSub-code7:ODUswitchoversucceeds.
EffectontheSystem
Thetrafcmaybeinterruptedfor300ms,andnoerrorcodeisgenerated.
PossibleCauses
1.TheRMUboardfails.
2.TheODUfails.
3.Theswitchovercanbecausedbylostorabnormalclocksignalfromtheenclosure,
hardresettingoftheboard,boardpower-off,orhardwarefaultoftheboard.
HandlingProcedure
Refertothehandlingsuggestionsofthecorrespondingalarms.
3.37134317745ACMchange
NoticationProperty
lNoticationCode:134317745
lNoticationInformation:Thenoticationisreportediftheradiolinkmodulationmode
ischanged.
lNoticationType:EquipmentAlarm
Sub-codeDescription
Eachsubcoderepresentsaslot.
EffectontheSystem
Themodulationmodeischanged,thetrafccapacityischanged,butthetrafcisnot
interrupted.