EasyManua.ls Logo

Zte ZXMW NR8250 - 134239928 Radio Link Failure Alarm

Zte ZXMW NR8250
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ZXMWNR8250AlarmandNoticationHandlingReference
lSub-code9:E1port9onthepanel;
lSub-code10:E1port10onthepanel;
lSub-code11:E1port11onthepanel;
lSub-code12:E1port12onthepanel;
lSub-code13:E1port13onthepanel;
lSub-code14:E1port14onthepanel;
lSub-code15:E1port15onthepanel;
lSub-code16:E1port16onthepanel;
lSub-code17:E1port17onthepanel;
lSub-code18:E1port18onthepanel;
lSub-code19:E1port19onthepanel;
lSub-code20:E1port20onthepanel;
lSub-code21:E1port21onthepanel;
lSub-code22:E1port22onthepanel;
lSub-code23:E1port23onthepanel;
lSub-code24:E1port24onthepanel;
lSub-code25:E1port25onthepanel;
lSub-code26:E1port26onthepanel;
lSub-code27:E1port27onthepanel;
lSub-code28:E1port28onthepanel;
lSub-code29:E1port29onthepanel;
lSub-code30:E1port30onthepanel;
lSub-code31:E1port31onthepanel;
lSub-code32:E1port32onthepanel.
EffectontheSystem
TheE1receiverelaysignalcarriedbytheTUisinterrupted.
PossibleCauses
1.TheupstreamE1signalsenttoNR8250equipmentisinvalid,thatis,everybitinthe
signalis"1".
2.TheRTUA/RTUB/RTUC/RTUHboardthatreportsthealarmisfaulty.
HandlingProcedure
1.CheckwhethertheupstreamdevicehasanAISalarm.
lIfyes,troubleshootthefaultydevice.Replacethefaultyboard.
lIfno,gotostep2.
2.ThealarmiscausedbyRTUA/RTUB/RTUC/RTUHboardfailure.Replacetheboard.
2.2.27134239928Radiolinkfailurealarm
AlarmProperty
lAlarmCode:134239928
2-44
SJ-20111008094748-008|2012–05–30(R1.1)ZTEProprietaryandCondential