fanspeed FanSpeedEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the fan speed
goes above or below the normal
operating range.
FanSpeedEventClear 1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the fan speed
returns to the normal operating
range.
temperature TemperatureEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the
temperature goes above or below
the normal operating range.
TemperatureEventClear 1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the
temperature returns to the normal
operating range.
voltage VoltageEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the voltage
goes above or below the normal
operating range.
VoltageEventClear 1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the voltage
returns to the normal operating
range.
reset UncontrolledResetEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the Switch
automatically resets.
ControlledResetEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the Switch
resets by an administrator through a
management interface.
RebootEvent 1.3.6.1.4.1.890.1.5.1.1.2 This trap is sent when the Switch
reboots by an administrator through
a management interface.
timesync RTCNotUpdatedEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the Switch
fails to get the time and date from a
time server.
RTCNotUpdatedEventClear 1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the Switch
gets the time and date from a time
server.
intrusionlock IntrusionLockEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when intrusion lock
occurs on a port.
loopguard LoopguardEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when loopguard
shuts down a port.
Table 79 SNMP System Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
Table 80 SNMP Interface Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
linkup linkUp 1.3.6.1.6.3.1.1.5.4 This trap is sent when the
Ethernet link is up.
LinkDownEventClear 1.3.6.1.4.1.890.1.5.8.xx.31.2.2 This trap is sent when the
Ethernet link is up.
linkdown linkDown 1.3.6.1.6.3.1.1.5.3 This trap is sent when the
Ethernet link is down.
LinkDownEventOn 1.3.6.1.4.1.890.1.5.8.xx.31.2.1 This trap is sent when the
Ethernet link is down.