29.3  PPPoE Intermediate Agent 
Use this screen to configure the Switch to give a PPPoE termination server additional subscriber 
information that the server can use to identify and authenticate a PPPoE client.
Click Advanced Application > PPPoE > Intermediate Agent in the navigation panel to display 
the screen as shown. 
Figure 178   Advanced Application > PPPoE > Intermediate Agent 
The following table describes the labels in this screen. 
Table 117   Advanced Application > PPPoE > Intermediate Agent
LABEL DESCRIPTION
Active Select this option to enable the PPPoE intermediate agent globally on the Switch.
access-node-
identifier
Enter up to 20 ASCII characters to identify the PPPoE intermediate agent. Hyphens (-) and 
spaces are also allowed. The default is the Switch’s host name. 
circuit-id Use this section to configure the Circuit ID field in the PADI and PADR packets. 
The Circuit ID you configure for a specific port or for a specific VLAN on a port has priority 
over this.
The Circuit ID you configure for a specific port (in the Advanced Application > PPPoE > 
Intermediate Agent > Port screen) or for a specific VLAN on a port (in the Advanced 
Application > PPPoE > Intermediate Agent > Port > VLAN screen) has priority over 
this. That means, if you also want to configure PPPoE IA Per-Port or Per-Port Per-VLAN 
setting, leave the fields here empty and configure circuit-id and remote-id in the Per-Port or 
Per-Port Per-VLAN screen.
Active  Select this option to have the Switch add the user-defined identifier string and variables 
(specified in the option field) to PADI or PADR packets from PPPoE clients.
If you leave this option unselected, the Switch will use the string specified in the access-
node-identifier field. 
identifier-
string 
Specify a string that the Switch adds in the Agent Circuit ID sub-option. You can enter up to 
53 ASCII characters. Spaces are allowed.
option Select the variables that you want the Switch to generate and add in the Agent Circuit ID 
sub-option. The variable options include sp, sv, pv and spv which indicate combinations of 
slot-port, slot-VLAN, port-VLAN and slot-port-VLAN respectively. The Switch enters a zero 
into the PADI and PADR packets for the slot value.