Chapter 35 Access Control
GS2200 Series User’s Guide
270
Table 116 SNMP Switch Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
stp STPNewRoot 1.3.6.1.2.1.17.0.1 This trap is sent when the STP root
switch changes.
MRSTPNewRoot 1.3.6.1.4.1.890.1.5.8.55.36.2.1
1.3.6.1.4.1.890.1.5.8.56.36.2.1
1.3.6.1.4.1.890.1.5.8.59.36.2.1
1.3.6.1.4.1.890.1.5.8.60.36.2.1
This trap is sent when the MRSTP root
switch changes.
MSTPNewRoot 1.3.6.1.4.1.890.1.5.8.55.107.70.1
1.3.6.1.4.1.890.1.5.8.56.107.70.1
1.3.6.1.4.1.890.1.5.8.59.107.70.1
1.3.6.1.4.1.890.1.5.8.60.107.70.1
This trap is sent when the MSTP root
switch changes.
STPTopologyChange 1.3.6.1.2.1.17.0.2 This trap is sent when the STP topology
changes.
MRSTPTopologyChange 1.3.6.1.4.1.890.1.5.8.55.36.2.2
1.3.6.1.4.1.890.1.5.8.56.36.2.2
1.3.6.1.4.1.890.1.5.8.59.36.2.2
1.3.6.1.4.1.890.1.5.8.60.36.2.2
This trap is sent when the MRSTP
topology changes.
MSTPTopologyChange 1.3.6.1.4.1.890.1.5.8.55.107.70.2
1.3.6.1.4.1.890.1.5.8.56.107.70.2
1.3.6.1.4.1.890.1.5.8.59.107.70.2
1.3.6.1.4.1.890.1.5.8.60.107.70.2
This trap is sent when the MSTP root
switch changes.
mactable MacTableFullEventOn 1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when more than 99% of
the MAC table is used.
MacTableFullEventClear 1.3.6.1.4.1.890.1.5.8.55.27.2.2
1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.59.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when less than 95% of
the MAC table is used.
rmon RmonRisingAlarm 1.3.6.1.2.1.16.0.1 This trap is sent when a variable goes
over the RMON "rising" threshold.
RmonFallingAlarm 1.3.6.1.2.1.16.0.2 This trap is sent when the variable falls
below the RMON "falling" threshold.
CFM dot1agCfmFaultAlarm 1.3.111.2.802.1.1.8.0.1 The trap is sent when the Switch detects
a connectivity fault.

Table of Contents