15.3 The Power Screen
Use this screen to manage power settings for the NSA, including power saving,
UPS, power on/off during power failure and power on/off schedule.
Click Maintenance > Power to display the following screen.
Figure 173 Maintenance > Power
The following table describes the labels in this screen.
Table 100 Maintenance > Power
LABEL DESCRIPTION
Power Management
Turn off hard
disk(s)
Enter the number of minutes the NSA will sit idle before spinning the
hard disks down to sleep. The default power-off time is 3 minutes.
Minimum UPS Capacity
Minimum UPS
Capacity
When you use an APC Uninterruptible Power Supply (UPS) with a USB
connection to the NSA, the NSA shuts itself down if the APC UPS’s
battery charge gets down to the percentage you specify in this field. This
allows the NSA to shut down properly and avoid data loss caused by a
power failure when the UPS stops supplying power.
A setting around 50% is recommended. A setting close to 100% is not
recommended since it would cause the NSA to shut down whenever the
UPS is charging. A setting close to 0 is also not recommended since the
UPS would not have enough power to allow the NSA to shutdown
properly.
Power On After
Power Failure
Select an option to set whether or not the NSA restarts when the power
is restored after a power failure.