Tariff pulse frequency (Function No. 112)
Tariff pulse frequency setting.
Setting options:   
16 kHz (0) –2N
®
EasyGate transmits 16 kHz tariff pulses
12 kHz (1) –2N
®
EasyGate transmits 12 kHz tariff pulses
Default setting: 16 kHz
Call progress signaling via CPC (Function No. 113)
Call end signaling setting via CPC – Calling Party Control. A short-time current interruption with
a phone loop for call end signaling.
Setting options:  Off (0)
              On (1)
Default setting:  Off
Tone Settings
Dial tone Double frequency tone [Hz] (Function No. –)
The parameter can be set for all the three tone types (Dial tone, Busy tone, Ringback tone). This
parameter is intended for switching between the single tone and double tone settings. When the
parameter is set, the other frequency of the appropriate tone must be set too. When this
parameter is not set, frequency 2 is automatically set to the same value, which results in single
tone generation. This parameter cannot be set using phone line programming. When phone line
programming is used for a frequency change, both tones must be set (for single frequency to the
same value).
Setting options: YES/NO
Default setting: NO
Dial tone frequency 1 [Hz] (Function No. 120)
Setting of dial tone frequency 1. This tone is generated after Off-Hook in case2N
®
EasyGate is
ready to accept dialing.
Setting options: 1–3400 Hz
Setting step: 1 Hz
Default setting: 425 Hz