EasyManuals Logo

2N EasyGate Pro User Manual

2N EasyGate Pro
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
User Guide 2N® EasyGate PRO
26 / 87
Tariff pulse frequency (Function No. 112)
Tariff pulse frequency setting.
Setting options:   
16 kHz (0) –2N
®
EasyGate transmits 16 kHz tariff pulses
12 kHz (1) –2N
®
EasyGate transmits 12 kHz tariff pulses
Default setting: 16 kHz
Call progress signaling via CPC (Function No. 113)
Call end signaling setting via CPC – Calling Party Control. A short-time current interruption with
a phone loop for call end signaling.
Setting options:  Off (0)
              On (1)
Default setting:  Off
Tone Settings
Dial tone Double frequency tone [Hz] (Function No. –)
The parameter can be set for all the three tone types (Dial tone, Busy tone, Ringback tone). This
parameter is intended for switching between the single tone and double tone settings. When the
parameter is set, the other frequency of the appropriate tone must be set too. When this
parameter is not set, frequency 2 is automatically set to the same value, which results in single
tone generation. This parameter cannot be set using phone line programming. When phone line
programming is used for a frequency change, both tones must be set (for single frequency to the
same value).
Setting options: YES/NO
Default setting: NO
Dial tone frequency 1 [Hz] (Function No. 120)
Setting of dial tone frequency 1. This tone is generated after Off-Hook in case2N
®
EasyGate is
ready to accept dialing.
Setting options: 1–3400 Hz
Setting step: 1 Hz
Default setting: 425 Hz

Other manuals for 2N EasyGate Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N EasyGate Pro and is the answer not in the manual?

2N EasyGate Pro Specifications

General IconGeneral
MountingDIN-rail
Device typeCellular network gateway
Built-in displayNo
Market positioningBusiness
Data networkGSM
SIM interface3 V
GSM bands supported850, 900, 1800, 1900 MHz
USB portYes
USB 2.0 ports quantity1
Antenna connector typeSMA
Input voltage100 - 240 V
Operating temperature (T-T)0 - 45 °C
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)163 x 157 x 38 mm

Related product manuals