EasyManua.ls Logo

2N EasyGate Pro - Page 36

2N EasyGate Pro
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide 2N® EasyGate PRO
36 / 87
Tariff [s] (Function No. 398)
Pseudo tariff metering setting (tariff is based on call duration). The Tariff parameter sets the call
cost according to call duration. Set how often in seconds you want to transmit pulses. A smaller
number means a more expensive call. Zero means not to transmit pulses according to call
duration.
Setting options: 0–255 s
Setting step: 1 s
Default setting: 0 s
Time limit [min] (Function No. 399)
After the time elapses, the call connection is terminated immediately. You can hear a beep 30 s
before the call end and beeps every second 10 s before the end. The "0" setting means that the
function is disabled.
Setting options: 0255 min
Setting step: 1 min
Default setting: 0 (disabled)
Bank No. (Function No. –)
Special function for FW 1.5x and 3.5x only. Do not use this parameter and the 'Free minute
bank' folder with detailed settings for standard 2N
®
EasyGate.
GSM,UMTS, LTE Routing Parameters
Incoming GSM calls contain the CLI. According to the received CLI2N
®
EasyGate can do the
following:
Reject the call.
Use the CallBack function – automatic call to the GSM subscriber.
Automatic dial in.2N
®
EasyGate dials the preprogrammed PBX subscriber number
(switchboard operator, e.g.) to be connected with the calling GSM subscriber.
FXS line Off-Hook to DISA timeout [ms] (Function No. 500)
Timeout between FXS line Off-Hook and automatic dial in according to the "Dial in" parameter
in the table.
Setting options: 100–25500 ms
Setting step: 100 ms
Default setting: 2000 ms

Other manuals for 2N EasyGate Pro

Related product manuals