14
4-SPECIFICATIONS
1. Power Requirements
Electrical: 115 VAC, 60 Hz, 6.4 A (675 watts)
Pneumatic: 85 PSIG [6 bar pressure], 2.5 SCFM
[70 liter/minute @ 2PC, 1.01 bar] maximum at maximum random cycle rate.
A pressure regulator/ lter is included
The machine is equipped with a 2.4m [8 foot] standard neoprene covered power cord and a grounded plug.
Contact your 3M Representative for power requirements not listed above.
2. Operating Rate
Box drive belt speed is approximately 0.5 m/s [100 feet per minute].
IMPORTANT SAFEGUARD
5. Tape Width
50mm [2 inches] minimum to 72mm [3 inches] maximum
4. Tape
Scotch
®
pressure-sensitive lm box sealing tapes.
3. Operating Conditions
Use in dry, relatively clean environments at 4.4
o
C to 48.9
o
C [40
o
F to 120
o
F] with clean, dry boxes.
Note: Machine should not be washed or subjected to conditions causing moisture condensation on
components.
0
5
10
15
20
25
30
35
40
45
0 5 10 15 20 25 30 35 40
To reduce the risk associated with re
and explosion hazards:
Do not operate this equipment in poten-
tially ammable or explosive environments.
WARNING