P/N 595369-01 Rev B 07/19
PROGRAMMING A PASS DEVICE WITH AN RFID TAG
3M recommends re-programming the PASS device with the RFID card in
accordance with your organization's procedures to assure that the user's unique ID
number is in use at all times. To program the identication of a PASS device with an
RFID Tag, proceed as follows:
1. Verify that the air cylinder is closed and there is no residual air in the system.
2. Verify that the electronics have been inactive for at least thirty (30) seconds.
3. On the Control Console, hold down the GRAY (Withdraw) button until the ID
light goes on. Release the button.
4. Within ten (10) seconds, hold your SEMS II ID Tag against the back of the
Control Console labeled "SCAN ID TAGS HERE."
5. To indicate the programming has been successful, the ID light will ash three
(3) times slowly and then go out.
6. When performing the REGULAR OPERATIONAL INSPECTION of the SEMS II
Pro Wireless SCBA Telemetry System, verify that the correct ID appears on the
Base Station display.
NOTE
ONCE THE RESPIRATOR HAS BEEN PRESSURIZED FOR USE, THE ID
CANNOT BE CHANGED. THE RESPIRATOR MUST BE SHUT DOWN AND
THERE MUST BE NO RESIDUAL AIR PRESSURE LEFT IN THE SYSTEM TO
CHANGE THE ID.
To manually remove the programmed RFID card number, verify that the air cylinder
is closed, there is no residual air in the system, and the PASS is in the off state.
Press and hold the YELLOW RESET Button for eight (8) seconds. During reset,
the red lights on the PASS console will alternately ash, indicating that the PASS
device is in programming mode. Use Congure and the Pak-Link Programmer
to program the Pak-ID. For more information, see the Scott Connect Congure
Instruction Guide available within Congure.
The unit will automatically return to the default ID number in either of the following
situations:
if the battery cover is opened and/or the batteries are removed
after twenty-four (24) hours
PRESSING THE GRAY (WITHDRAW)
BUTTON
PROGRAMMING THE USER ID WITH THE RFID TAG
ID LIGHT WILL FLASH 3
TIMES SLOWLY TO INDICATE
SUCCESSFUL PROGRAM
WARNING
PROGRAMMING A PASS DEVICE USING A RFID
TAG, BADGE, OR BUTTON OVERWRITES THE
PAK-ID FOR 24 HOURS. IF THE SCBA IS USED
WITHIN 24 HOURS OF PROGRAMMING WITH
AN RFID TAG, BADGE, OR BUTTON, THE NEW
ID IS TRANSMITTED TO THE PAK-TRACKER AND
TO MONITOR. AFTER THAT TIME, THE PAK-ID
DEFAULTS TO THE ID SET USING CONFIGURE
AND THE PAK-LINK PROGRAMMER. IF NO ID
WAS SET, THEN THE ID DEFAULTS TO THE
FACTORY-SET ID.
WARNING
DO NOT USE AN RFID TAG READER THAT HAS
AN OUTPUT POWER GREATER THAN 6 WATTS
WHILE IN A FLAMMABLE ATMOSPHERE.