Page 24 of 28
P/N 595369-01 Rev B 07/19
INTRINSICALLY SAFE LISTING
The PASS device with Integrated Locator transmitter, Model Number 201160-SERIES,
when installed on a 3M Scott Air-Pak X3 Pro SCBA, is listed by SGS U.S. TESTING
COMPANY INC. as intrinsically safe per ANSI/UL Std. UL-913 for use in Class I, II,
Division 1, Groups C, D, E, F, and G Hazardous Locations, only when powered by
the batteries listed in this instruction or indicated on the label on the Sensor Module.
To maintain Intrinsic Safety Listing, inspect the respirator with a PASS device
regularly per the Regular Operational Inspection procedures in this instruction.
Substitution of components may impair intrinsic safety. To reduce the risk of
ignition of a ammable atmosphere, batteries must only be changed in an area
known to be nonammable. To reduce the risk of explosion, use only the approved
batteries, do not mix old batteries with unused batteries, or mix batteries from
different manufacturers.
HAND HELD RECEIVER NON-INCENDIVE LISTING
The HHR (P/N 200397-04) is listed by SGS U. S. TESTING COMPANY, Inc. as
Non-Incendive per ISA Std. 12.12.01 and UL 1604 for use in Class I Division 2
Groups A, B, C, and D hazardous locations. Temperature Code T4 (-25° C to
85° C). To maintain the Non-Incendive Listing, the equipment must be inspected
regularly per the following Regular Operational Inspection procedures. Do not
tamper with or substitute components in any manner. Use only battery pack P/N
200402-02. Open the battery compartment only in an area known to be free of
ammable or explosive hazards.
WARNING – Substitution of components may impair the non-incendive listing
To reduce the risk of ignition of a ammable atmosphere, battery must only be
changed in an area known to be nonammable. Do not substitute any other battery
or power source.
WARNING
IF THE PASS DEVICE IS USED IN AN AREA
OF EXPLOSIVE OR FLAMMABLE HAZARDS,
FAILURE TO REGULARLY INSPECT AS
INSTRUCTED, FAILURE TO CORRECT DAMAGE
BEFORE USE, OR THE INSTALLATION OF
INCORRECT BATTERIES MAY LEAD TO A
FIRE OR EXPLOSION, WHICH MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING
FAILURE TO REGULARLY INSPECT THE HHR AS
DESCRIBED IN THIS INSTRUCTION OR FAILURE
TO CORRECT ANY DAMAGE FOUND MAY
IMPAIR THE SAFETY OF THE EQUIPMENT. THE
INSTALLATION OF INCORRECT BATTERY OR
SUBSTITUTION OF ANY OTHER COMPONENTS
MAY IMPAIR THE SAFETY OF THE EQUIPMENT.
IF THE EQUIPMENT IS USED IN AN EXPLOSIVE
OR FLAMMABLE ATMOSPHERE, IMPAIRING
THE SAFETY OF THE UNIT MAY LEAD TO A FIRE
OR AN EXPLOSION WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
WARNING
REPLACE THE HHR BATTERY PACK ONLY
WITH BATTERY PACK, PART NO. 200402-
02. DO NOT REMOVE, RE-CHARGE, OR
REPLACE THE BATTERY PACK WHILE THE
DEVICE IS IN A HAZARDOUS LOCATION.
REMOVING, RE-CHARGING, OR REPLACING
THE BATTERY PACK WHILE THE DEVICE IS IN
A HAZARDOUS LOCATION MAY LEAD TO A FIRE
OR AN EXPLOSION, WHICH COULD RESULT IN
SERIOUS INJURY OR DEATH.
WARNING
RADIO FREQUENCY INTERFERENCE (RFI)
MAY CAUSE A MALFUNCTION OF THE PASS
DEVICE. USERS OF RESPIRATORS EQUIPPED
WITH A PASS DEVICE MUST BE AWARE OF
THE PROPER OPERATION OF THE DEVICE.
FAILURE TO RECOGNIZE A MALFUNCTION
OF THE EQUIPMENT AND TAKE PROPER COR-
RECTIVE ACTION MAY RESULT IN FAILURE
OF THE PASS DEVICE AND LEAD TO SERIOUS
INJURY OR DEATH.
RADIO FREQUENCY INTERFERENCE (RFI)
When any electronic device is adversely affected by radio waves, radio frequency
interference (RFI) is said to have occurred. All electronic devices like the PASS
device may be subject to the effects of RFI, most of which are temporary in nature.
Users of the 3M Scott Air-Pak X3 Pro SCBA with PASS device must be familiar with
the normal operation of the device and must also be familiar with how to identify and
avoid the effects of RFI (see DETECTING AND AVOIDING RADIO FREQUENCY IN-
TERFERENCE). If RFI occurs to the PASS device, it may be caused by transmissions
from hand-held or personal radios where the radio antenna is touching or very close
to (less than 6 inches from) components of the PASS device. It may also be caused
by transmissions from Base Stations or high-powered vehicle mounted radios or any
other powerful source of electromagnetic radiation.
WARNING
SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY. TO REDUCE THE RISK OF
IGNITION OF A FLAMMABLE ATMOSPHERE,
BATTERIES MUST ONLY BE CHANGED IN AN
AREA KNOWN TO BE NONFLAMMABLE. TO
REDUCE THE RISK OF EXPLOSION, DO NOT
MIX OLD BATTERIES WITH UNUSED BATTERIES
OR MIX BATTERIES FROM DIFFERENT
MANUFACTURERS.
WARNING
DO NOT USE AN RFID TAG READER THAT HAS
AN OUTPUT POWER GREATER THAN 6 WATTS
WHILE IN A FLAMMABLE ATMOSPHERE.