Page 25 of 28
P/N 595369-01 Rev B 07/19
SEMS II PRO INTEGRATED PASS DEVICE
PERFORMANCE SPECIFICATIONS
Sound Levels:
Pre-Alarm... .............................. 85 to 105 dBA incrementally at left ear
Full-Alarm ................................. 95 to 100 dBA @ 9.9 Ft. (3m)
Frequency Range ..................... 1.5 KHz to 4 KHz
Battery Life (fresh batteries)
Alkaline Batteries:
Automatic (green ashing light, no sound) ...................... Approx. 20 hours
Full Alarm (red ashing light, 95 dBA sound)................. Approx. 8 hours
Compliance
The PASS device is a NIOSH approved accessory for use on only the following 3M
Scott Fire & Safety SCBAs:
3M SCOTT AIR-PAK X3 PRO SCBA - SNAP-CHANGE & CGA
2.2 (30 MIN.)
4.5 (30 MIN.)
4.5 (45 MIN.)
4.5 (60 MIN.)
5.5 (30 MIN.)
5.5 (45 MIN.)
5.5 (60 MIN.)
5.5 (75 MIN.)
PERSONAL COMPUTER
The personal computer Base Station environmental operating parameters are
totally dependant on the limitations of the personal computer used with the SEMS
II Pro Wireless SCBA Telemetry System. Do not use the personal computer Base
Station in environments for which it is not designed. Handle the personal computer
according to the instructions provided with the personal computer.
EXPORT AND IMPORT
The international transport of the SEMS II Pro Wireless SCBA Telemetry System
and portions thereof is regulated under United States export regulations and may
be regulated by the import regulations of other countries.
If you have any questions or concerns regarding these regulations, contact the
company at 1-800-247-7257 (or 704-291-8300 outside the continental United
States).
NOTE
DO NOT USE A FIBERGLASS WRAPPED ONE HOUR CYLINDER ON A MODEL 4.5
AIR-PAK SCBA EQUIPPED WITH A PASS DEVICE AS THE WEIGHT WILL EXCEED
THE 35-LB APPROVAL LIMIT FOR SCBA’s ESTABLISHED BY NIOSH.
END USER LICENSE AGREEMENT
Software and/or rmware incorporated in this 3M Scott product is subject to the
terms of an End User License Agreement (EULA), which are stated in the software
download and installation process.