16
IN SHOW MODE
24’ - 080 Camera speed and Remaining footage (default mode)
ISO = 100 Film ASA (1 x Batt/Iso)
Batt = 10’4 Battery voltage (2 x Batt/Iso)
MAG =0071 Magazine number (3 x Batt/Iso)
Sp = 27’454 Camera Speed (1 x Speed)
Ela = 042 Elapsed footage during last take (2 x Speed)
22=32=54 Hours=minutes=seconds in AatonCode (1 x Time)
95-03-25 Year-Month-Day in AatonCode (2 x Time)
123456 Production ID in AatonCode (3 x Time)
2321 Equipment number in AatonCode (4 x Time)
IN SET MODE
Sp =2 4’ Adjusting a preset speed (SET, 1 x SYNC, toggle SYNC or use Jog)
Sp = 27’454 Adjusting a specific speed (SET, 1 x VAR, use Jog)
Et Speed controled by external speed device (SET, 2 x VAR)
Phase Phase Adjusting (Camera running,SET, 2 x VAR, use Jog)
ISO = 100 ASA Setting (SET, 1 x ISO, toggle ISO or use Jog)
WARNINGS
Lo Spd Camera has not yet reached the selected speed
Lo Batt Battery is too low (below 10V)
Loop Film loop is too small
Scratch Something is wrong in the magazine
Empty No more film in the magazine
Unadjust Please check page 39
1.5 LCD CONTROL PANEL - QUICK REFERENCE
Test
Run
Time speed
ISO / Batt
VAR
SYNC
ISO
SET