Operation Manual / 4 Product description / A130-M.. - A145-M..
2 Removing and Installing / 2.2 Removing the turbocharger
© Copyright 2020 ABB. All rights reserved. HZTL4031_EN Rev.L July 2020
The gas outlet casing(61001) can remain fitted in the exhaust gas pipe if the locking nuts
are accessible. Otherwise the complete turbocharger unit including gas outlet casing must
be removed.
u If present: Loosen and remove the compressor wheel cooling connection. Close the com-
pressor wheel cooling opening with a screw plug(01).
u If present: Disconnect the plug to the speed sensor (86505) and secure the rolled-up
cable on the turbocharger. This protects the plug from being crushed.
Fig.7: Removing the turbocharger
A Oil-cooled bearing casing D Clamping nut
B Water-cooled bearing casing E Standard nut
C Position of expansion sleeves
u Apply penetrating oil to thread of stud (02) and nut and let it work in.
Do not oil the pressure screws of the clamping nut(D).
u If present: Detach the support (61301) from the engine support.
Depending on the bracket version(04), two positioning pins(05) can be used for positioning
and safeguarding against wrong fitting of the turbocharger. Therefore the turbocharger
must always be removed from and installed on the bracket vertically.