5.4 Stopping the engine
CAUTION
Residual heat in the turbocharger
If the residual heat in the turbocharger is not adequately dissipated, it may
damage the engine.
u Adequate cooling of the turbocharger must be ensured after stopping
the engine.
u Run the engine for 5...10 minutes at idling speed before stopping it.
u Observe the oil pressure specified for engine idling (see Table6: Lubricating oil pressure
at oil inlet before turbocharger 27).
¡ Post-lubricate water-cooled bearing casings until the rotors come to a standstill. Deac-
tivate post-lubrication as soon as the rotor comes to a standstill. Deviating procedures
must be coordinated with ABB Turbocharging.
¡ For oil-cooled bearing casings, post-lubricate for 20minutes if the turbine inlet temper-
ature (t
TE
) exceeds the following values when the engine is stopped:
550°C with insulated casing
600°C with non-insulated casing
At temperatures below the specified values, post-lubrication must be ensured until the
rotors come to a standstill. ABB Turbocharging recommends post-lubrication for
10minutes.
u Observe the oil pressure specified for post-lubrication (see Table6: Lubricating oil pres-
sure at oil inlet before turbocharger 27).
Page 41 / 114

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB A135-M55 and is the answer not in the manual?

ABB A135-M55 Specifications

General IconGeneral
BrandABB
ModelA135-M55
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals